ATEX SLCX
ATEX SLCX
SLCX
- 11 standard sizes from 355mm to 710mm
- Air volume flow rates up to 6.8 m3/s.
- Static pressures of up to 800 Pa.
- Suitable for operating temperatures up to +40°C.
- Suitable for extract or supply systems.
Compare
The SLCX is a range of ATEX rated duct mounted axial fans, manufactured in heavy gauge sheet steel. These units are designed to meet the requirements for Hazardous Areas with carbon filled anti-static impeller blades.
FEATURES & BENEFITSLearn more about individual features and benefits of our products. |
SPECIFICATIONThe SLCX range of ATEX fans as manufactured by Elta Fans Ltd. |
TECHNICAL INFORMATIONThe technical information available to you from ELTA Fans is exhaustive - Choose from either sound, performance and electrical or dimensional data for each and every product |
ACCESSORIESElta supply a full range of accessories for each of their products. |
COMPAREChoose up to three products to compare their features side-by-side. |
DOWNLOADSGet the full brochure, wiring diagrams and operation and maintenance instructions. |
Features & Benefits
Design appeal
Classified for constructional safety and the requirements stated in 94/4/EU (ATEX) directive, Gas Zone and ignition temperature protection to Ex II 2G c IIC T4 X
Material strength
Fan casings are heavy guage, sheet steel, roll formed and welded and hot dipped galvanised after fabrication to BS 729.
Warranty
Each SLCX has a 12 month warranty.
Performance
Adjustable pitch aerofoil section impellers with blades made from high quality carbon filled anti – static material for enhanced performance. Hubs are die cast aluminium.
Mounting
Fans can be mounted in any position.
Full accessory range
Speed controllers, Motor protection.
Quality assurance
All units are designed and manufactured with procedures as defined in BS EN ISO 9001: 2008.

Specification
The SLCX range of ATEX fans as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Contact us.
Casing
The all metal fan casing provides a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing. All casing parts are heavy gauge mild steel sheet, roll formed and welded, then hot dipped galvanised to BS 729 after fabrication.
Motors
Impellers
Impeller Adjustable pitch aerofoil impellers are provided with blades made from high quality carbon filled anti – static material, Impellers are factory set at an angle to provide maximum performance. Hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are dynamically balanced and vibration to ISO 14695:2003.
Quality Management

Technical Information
Performance and Sound Data
THREE Phase - 380-415V / 50Hz
|
Product Code |
Speed r/min |
Airflow SFP |
Airflow m³/s @ Static Pressure Pa. |
Overall Efficiency % |
FMEG |
Motor Electrical Data | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0 |
25 |
50 |
75 |
100 |
150 |
200 |
250 |
300 |
350 |
400 |
500 |
FLCAmps |
SCAmps |
OutputkW |
|||||
|
SLCX355/4-3 |
1360 |
m³/s |
0.86 |
0.82 |
0.77 |
0.72 |
0.65 |
28.4 |
- |
1.1 |
3.74 |
0.37 |
|||||||
|
W/(L/s) |
0.28 |
0.32 |
0.36 |
0.40 |
0.45 |
||||||||||||||
|
SLCX400/2-3 |
2820 |
m³/s |
2.60 |
2.55 |
2.51 |
2.46 |
2.42 |
2.32 |
2.22 |
2.12 |
2 |
1.86 |
1.69 |
44.6 |
- |
5.0 |
2.8 |
2.2 |
|
|
W/(L/s) |
0.79 |
0.80 |
0.82 |
0.83 |
0.85 |
0.88 |
0.92 |
0.96 |
1.02 |
1.08 |
1.18 |
||||||||
|
SLCX400/4-3 |
1390 |
m³/s |
1.34 |
1.29 |
1.24 |
1.17 |
1.09 |
0.85 |
31.1 |
- |
1.6 |
6.56 |
0.55 |
||||||
|
W/(L/s) |
0.36 |
0.38 |
0.41 |
0.44 |
0.47 |
0.60 |
|||||||||||||
|
SLCX450/2-3A |
2820 |
m³/s |
3 |
2.96 |
2.93 |
2.89 |
2.85 |
2.76 |
2.68 |
2.59 |
2.49 |
2.38 |
2.25 |
1.90 |
60.4 |
- |
5 |
2.8 |
2.2 |
|
W/(L/s) |
0.47 |
0.49 |
0.51 |
0.53 |
0.55 |
0.60 |
0.65 |
0.69 |
0.75 |
0.80 |
0.87 |
1.05 |
|||||||
|
SLCX450/4-3B |
1390 |
m³/s |
1.98 |
1.90 |
1.83 |
1.75 |
1.67 |
1.44 |
57.6 |
- |
9.75 |
7.79 |
9.75 |
||||||
|
W/(L/s) |
0.32 |
0.35 |
0.38 |
0.41 |
0.45 |
0.54 |
|||||||||||||
|
SLCX500/2-3 |
2820 |
m³/s |
3.64 |
3.58 |
3.53 |
3.47 |
3.41 |
3.29 |
3.17 |
3.04 |
2.91 |
2.78 |
2.62 |
2.27 |
48.1 |
- |
5 |
28 |
2.2 |
|
W/(L/s) |
0.56 |
0.57 |
0.59 |
0.60 |
0.62 |
0.66 |
0.72 |
0.78 |
0.86 |
0.95 |
1.05 |
1.27 |
|||||||
|
SLCX500/2-3B |
2900 |
m³/s |
3.96 |
3.92 |
3.88 |
3.84 |
3.80 |
3.72 |
3.65 |
3.57 |
3.50 |
3.43 |
3.35 |
3.20 |
53.0 |
- |
8 |
56 |
4 |
|
W/(L/s) |
0.89 |
0.91 |
0.93 |
0.95 |
0.97 |
1 |
1.04 |
1.09 |
1.13 |
1.17 |
1.22 |
1.32 |
|||||||
|
SLCX500/4-3 |
1380 |
m³/s |
2.67 |
2.58 |
2.49 |
2.41 |
2.32 |
2.08 |
1.68 |
41.0 |
- |
2.7 |
11.1 |
1.1 |
|||||
|
W/(L/s) |
0.37 |
0.40 |
0.43 |
0.45 |
0.47 |
0.53 |
0.64 |
||||||||||||
|
SLCX560/4-3 |
1380 |
m³/s |
3.74 |
3.65 |
3.55 |
3.45 |
3.35 |
3.10 |
2.75 |
46.4 |
- |
3.5 |
15.4 |
1.5 |
|||||
|
W/(L/s) |
0.38 |
0.41 |
0.43 |
0.45 |
0.48 |
0.53 |
0.60 |
||||||||||||
|
SLCX630/4-3 |
1410 |
m³/s |
5.40 |
5.29 |
5.15 |
5 |
4.86 |
4.57 |
4.23 |
3.74 |
51.0 |
- |
6.5 |
35.75 |
3.0 |
||||
|
W/(L/s) |
0.42 |
0.44 |
0.47 |
0.49 |
0.51 |
0.56 |
0.61 |
0.69 |
|||||||||||
|
SLCX710/4-3 |
1410 |
m³/s |
6.66 |
6.52 |
6.38 |
6.24 |
6.10 |
5.81 |
5.46 |
5 |
4.36 |
55.9 |
- |
6.5 |
35.75 |
3.0 |
|||
|
W/(L/s) |
0.38 |
0.40 |
0.43 |
0.45 |
0.47 |
0.52 |
0.57 |
0.62 |
0.71 |
||||||||||
Sound Data
THREE Phase - 380V-415V / 50Hz
|
Product Code |
In-duct Sound Power Level dBA @ Octave Band |
dBA @ 3m | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
63Hz |
125Hz |
250Hz |
500Hz |
1 kHz |
2 kHz |
4 kHz |
8 kHz |
|||
|
SLCX355/4-3 |
Inlet |
64 |
68 |
69 |
62 |
66 |
65 |
59 |
48 |
50 |
|
Outlet |
67 |
67 |
72 |
64 |
64 |
63 |
60 |
53 |
49 |
|
|
SLCX400/2-3 |
Inlet |
83 |
81 |
82 |
79 |
76 |
73 |
71 |
66 |
61 |
|
Outlet |
80 |
85 |
83 |
77 |
75 |
73 |
69 |
64 |
61 |
|
|
SLCX400/4-3 |
Inlet |
69 |
68 |
69 |
68 |
70 |
68 |
62 |
54 |
53 |
|
Outlet |
70 |
69 |
73 |
70 |
67 |
66 |
63 |
56 |
53 |
|
|
SLCX450/2-3A |
Inlet |
88 |
81 |
84 |
81 |
84 |
82 |
80 |
72 |
68 |
|
Outlet |
84 |
82 |
86 |
81 |
84 |
82 |
80 |
76 |
68 |
|
|
SLCX450/4-3B |
Inlet |
72 |
71 |
72 |
71 |
73 |
71 |
65 |
57 |
56 |
|
Outlet |
73 |
72 |
76 |
73 |
70 |
69 |
66 |
59 |
56 |
|
|
SLCX500/2-3 |
Inlet |
95 |
83 |
88 |
87 |
90 |
85 |
84 |
79 |
73 |
|
Outlet |
85 |
82 |
89 |
86 |
89 |
87 |
84 |
80 |
73 |
|
|
SLCX500/2-3B |
Inlet |
91 |
86 |
88 |
95 |
97 |
94 |
92 |
88 |
80 |
|
Outlet |
92 |
87 |
89 |
95 |
95 |
94 |
92 |
88 |
80 |
|
|
SLCX500/4-3 |
Inlet |
71 |
73 |
74 |
76 |
79 |
76 |
75 |
64 |
62 |
|
Outlet |
78 |
75 |
78 |
75 |
74 |
73 |
71 |
64 |
59 |
|
|
SLCX560/4-3 |
Inlet |
77 |
75 |
80 |
80 |
82 |
79 |
78 |
70 |
66 |
|
Outlet |
80 |
78 |
81 |
79 |
77 |
76 |
74 |
68 |
62 |
|
|
SLCX630/4-3 |
Inlet |
80 |
73 |
81 |
80 |
82 |
78 |
79 |
72 |
66 |
|
Outlet |
81 |
80 |
83 |
81 |
80 |
78 |
77 |
70 |
65 |
|
|
SLCX710/4-3 |
Inlet |
83 |
79 |
85 |
86 |
84 |
80 |
80 |
72 |
68 |
|
Outlet |
87 |
84 |
87 |
87 |
86 |
84 |
84 |
75 |
71 |
|
Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW.
The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.
Dimensional Data
|
Product Code |
A |
B |
C |
D |
E |
F |
G |
K |
Weight kg |
|---|---|---|---|---|---|---|---|---|---|
|
SLCX355/4-3 |
355 |
425 |
375 |
255 |
8 |
10 |
395 |
M20 |
29 |
|
SLCX400/2-3 |
400 |
475 |
400 |
270 |
8 |
12 |
450 |
M20 |
43 |
|
SLCX400/4-3 |
400 |
475 |
400 |
270 |
8 |
12 |
450 |
M20 |
35 |
|
SLCX450/2-3A |
450 |
530 |
450 |
290 |
8 |
12 |
500 |
M20 |
47 |
|
SLCX450/4-3B |
450 |
530 |
450 |
290 |
8 |
12 |
500 |
M20 |
40 |
|
SLCX500/2-3 |
500 |
585 |
450 |
310 |
12 |
12 |
560 |
M20 |
51 |
|
SLCX500/2-3B |
500 |
585 |
450 |
310 |
12 |
12 |
560 |
M20 |
68 |
|
SLCX500/4-3 |
500 |
585 |
450 |
310 |
12 |
12 |
560 |
M20 |
47 |
|
SLCX560/4-3 |
560 |
645 |
450 |
340 |
12 |
12 |
620 |
M20 |
63 |
|
SLCX630/4-3 |
630 |
715 |
450 |
355 |
12 |
12 |
690 |
M20 |
64 |
|
SLCX710/4-3 |
710 |
795 |
450 |
385 |
16 |
12 |
770 |
M20 |
70 |
Wiring Data
THREE Phase - 380V-415V / 50Hz
|
Product Code |
Wiring Diagram No. |
|---|---|
|
SLCX355/4-3 |
152-612 |
|
SLCX400/2-3 |
152-612 |
|
SLCX400/4-3 |
152-612 |
|
SLCX450/2-3A |
152-612 |
|
SLCX450/4-3B |
152-612 |
|
SLCX500/2-3 |
152-612 |
|
SLCX500/2-3B |
152-612 |
|
SLCX500/4-3 |
152-612 |
|
SLCX560/4-3 |
152-612 |
|
SLCX630/4-3 |
152-612 |
|
SLCX710/4-3 |
152-612 |
Accessories
Bell Mouth inlets (241B)
Fits directly to the fan case flange and provides easy connection to flexible connector
Read more
Impeller Guards (078C)
Bright Zinc plated Steel or glavanised. Fix with clips & screws (included)
Read more
Matching Flanges (061B)
Provides easy connection to flexible connector or ducting
Read more
Mounting Feet (060B)
For free standing mounting of ducted fans
Read more
Silencers (068-D**P)
Pre-galvanised sheet steel with perforated steel lining
Read more
Av Mounts (Rubber)
Spring AV mounts - zinc plated steel, rubber insert and foot pad
Read more
Flexible Connectors (063)
Fits directly to matching flanges providing a flexible connection between the fan and duct or ancilliaries.
Read more


Return to