ATEX SLCX
ATEX SLCX

ATEX SLCX

Left Arrow Return to ATEX
Left Arrow Return to Products

ATEX SLCX

samf main
 

The SLCX is a range of ATEX rated duct mounted axial fans, manufactured in heavy gauge sheet steel. These units are designed to meet the requirements for Hazardous Areas with carbon filled anti-static impeller blades.

samf f&b_box

FEATURES & BENEFITS

Learn more about individual features and benefits of our products.

samf spec_box

SPECIFICATION

The SLCX range of ATEX fans as manufactured by Elta Fans Ltd.

Technical information

TECHNICAL INFORMATION

The technical information available to you from ELTA Fans is exhaustive - Choose from either sound, performance and electrical or dimensional data for each and every product

Accessories

ACCESSORIES

Elta supply a full range of accessories for each of their products.

Compare

COMPARE

Choose up to three products to compare their features side-by-side.

Downloads

DOWNLOADS

Get the full brochure, wiring diagrams and operation and maintenance instructions.

SPP Features and Benefits
 

Features & Benefits


Design appeal

Classified for constructional safety and the requirements stated in 94/4/EU (ATEX) directive, Gas Zone and ignition temperature protection to  Ex II 2G c IIC T4 X

Material strength

Fan casings are heavy guage, sheet steel, roll formed and welded and hot dipped galvanised after fabrication to BS 729.

Warranty

Each SLCX has a 12 month warranty.

Performance

Adjustable pitch aerofoil section impellers with blades made from high quality carbon filled anti – static material for enhanced performance. Hubs are die cast aluminium.

Mounting

Fans can be mounted in any position.

Full accessory range

Speed controllers, Motor protection.

Quality assurance

All units are designed and manufactured with procedures as defined in BS EN ISO 9001: 2008.

SPP Specifications

Specification

The SLCX range of ATEX fans as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Contact us.


Casing

The all metal fan casing provides a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing. All casing parts are heavy gauge mild steel sheet, roll formed and welded, then hot dipped galvanised to BS 729 after fabrication.


Motors

Motors according to Gas Zone, Ignition Temperature and Protection to  Ex II 2G c IIC T4 X

 


Impellers

Impeller Adjustable pitch aerofoil impellers are provided with blades made from high quality carbon filled anti – static material, Impellers are factory set at an angle to provide maximum performance. Hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are dynamically balanced and vibration to ISO 14695:2003.


Quality Management

Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001: 2008. All ATEX units are to be tested to ISO 5801:1997 (airside performance) and BS 848 Part 2: 1985 (sound performance).

tech-ad

Technical Information


Performance and Sound Data

THREE Phase - 380-415V / 50Hz

Product Code

Speed r/min

Airflow SFP

Airflow m³/s @ Static Pressure Pa.

Overall Efficiency %

FMEG

Motor Electrical Data

0

25

50

75

100

150

200

250

300

350

400

500

FLCAmps

SCAmps

OutputkW

SLCX355/4-3

1360

m³/s

0.86

0.82

0.77

0.72

0.65

28.4

-

1.1

3.74

0.37

W/(L/s)

0.28

0.32

0.36

0.40

0.45

SLCX400/2-3

2820

m³/s

2.60

2.55

2.51

2.46

2.42

2.32

2.22

2.12

2

1.86

1.69

44.6

-

5.0

2.8

2.2

W/(L/s)

0.79

0.80

0.82

0.83

0.85

0.88

0.92

0.96

1.02

1.08

1.18

SLCX400/4-3

1390

m³/s

1.34

1.29

1.24

1.17

1.09

0.85

31.1

-

1.6

6.56

0.55

W/(L/s)

0.36

0.38

0.41

0.44

0.47

0.60

SLCX450/2-3A

2820

m³/s

3

2.96

2.93

2.89

2.85

2.76

2.68

2.59

2.49

2.38

2.25

1.90

60.4

-

5

2.8

2.2

W/(L/s)

0.47

0.49

0.51

0.53

0.55

0.60

0.65

0.69

0.75

0.80

0.87

1.05

SLCX450/4-3B

1390

m³/s

1.98

1.90

1.83

1.75

1.67

1.44

57.6

-

9.75

7.79

9.75

W/(L/s)

0.32

0.35

0.38

0.41

0.45

0.54

SLCX500/2-3

2820

m³/s

3.64

3.58

3.53

3.47

3.41

3.29

3.17

3.04

2.91

2.78

2.62

2.27

48.1

-

5

28

2.2

W/(L/s)

0.56

0.57

0.59

0.60

0.62

0.66

0.72

0.78

0.86

0.95

1.05

1.27

SLCX500/2-3B

2900

m³/s

3.96

3.92

3.88

3.84

3.80

3.72

3.65

3.57

3.50

3.43

3.35

3.20

53.0

-

8

56

4

W/(L/s)

0.89

0.91

0.93

0.95

0.97

1

1.04

1.09

1.13

1.17

1.22

1.32

SLCX500/4-3

1380

m³/s

2.67

2.58

2.49

2.41

2.32

2.08

1.68

41.0

-

2.7

11.1

1.1

W/(L/s)

0.37

0.40

0.43

0.45

0.47

0.53

0.64

SLCX560/4-3

1380

m³/s

3.74

3.65

3.55

3.45

3.35

3.10

2.75

46.4

-

3.5

15.4

1.5

W/(L/s)

0.38

0.41

0.43

0.45

0.48

0.53

0.60

SLCX630/4-3

1410

m³/s

5.40

5.29

5.15

5

4.86

4.57

4.23

3.74

51.0

-

6.5

35.75

3.0

W/(L/s)

0.42

0.44

0.47

0.49

0.51

0.56

0.61

0.69

SLCX710/4-3

1410

m³/s

6.66

6.52

6.38

6.24

6.10

5.81

5.46

5

4.36

55.9

-

6.5

35.75

3.0

W/(L/s)

0.38

0.40

0.43

0.45

0.47

0.52

0.57

0.62

0.71

Sound Data

THREE Phase - 380V-415V / 50Hz

Product Code

 

In-duct Sound Power Level dBA @ Octave Band

dBA @ 3m

63Hz

125Hz

250Hz

500Hz

1 kHz

2 kHz

4 kHz

8 kHz

SLCX355/4-3

Inlet

64

68

69

62

66

65

59

48

50

Outlet

67

67

72

64

64

63

60

53

49

SLCX400/2-3

Inlet

83

81

82

79

76

73

71

66

61

Outlet

80

85

83

77

75

73

69

64

61

SLCX400/4-3

Inlet

69

68

69

68

70

68

62

54

53

Outlet

70

69

73

70

67

66

63

56

53

SLCX450/2-3A

Inlet

88

81

84

81

84

82

80

72

68

Outlet

84

82

86

81

84

82

80

76

68

SLCX450/4-3B

Inlet

72

71

72

71

73

71

65

57

56

Outlet

73

72

76

73

70

69

66

59

56

SLCX500/2-3

Inlet

95

83

88

87

90

85

84

79

73

Outlet

85

82

89

86

89

87

84

80

73

SLCX500/2-3B

Inlet

91

86

88

95

97

94

92

88

80

Outlet

92

87

89

95

95

94

92

88

80

SLCX500/4-3

Inlet

71

73

74

76

79

76

75

64

62

Outlet

78

75

78

75

74

73

71

64

59

SLCX560/4-3

Inlet

77

75

80

80

82

79

78

70

66

Outlet

80

78

81

79

77

76

74

68

62

SLCX630/4-3

Inlet

80

73

81

80

82

78

79

72

66

Outlet

81

80

83

81

80

78

77

70

65

SLCX710/4-3

Inlet

83

79

85

86

84

80

80

72

68

Outlet

87

84

87

87

86

84

84

75

71

Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW.

The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.

Dimensional Data

Product Code

A

B

C

D

E

F

G

K

Weight kg

SLCX355/4-3

355

425

375

255

8

10

395

M20

29

SLCX400/2-3

400

475

400

270

8

12

450

M20

43

SLCX400/4-3

400

475

400

270

8

12

450

M20

35

SLCX450/2-3A

450

530

450

290

8

12

500

M20

47

SLCX450/4-3B

450

530

450

290

8

12

500

M20

40

SLCX500/2-3

500

585

450

310

12

12

560

M20

51

SLCX500/2-3B

500

585

450

310

12

12

560

M20

68

SLCX500/4-3

500

585

450

310

12

12

560

M20

47

SLCX560/4-3

560

645

450

340

12

12

620

M20

63

SLCX630/4-3

630

715

450

355

12

12

690

M20

64

SLCX710/4-3

710

795

450

385

16

12

770

M20

70

Wiring Data

THREE Phase - 380V-415V / 50Hz

Product Code

Wiring Diagram No.

SLCX355/4-3

152-612

SLCX400/2-3

152-612

SLCX400/4-3

152-612

SLCX450/2-3A

152-612

SLCX450/4-3B

152-612

SLCX500/2-3

152-612

SLCX500/2-3B

152-612

SLCX500/4-3

152-612

SLCX560/4-3

152-612

SLCX630/4-3

152-612

SLCX710/4-3

152-612

Accessories

  • Bell Mouth inlets (241B)

    Fits directly to the fan case flange and provides easy connection to flexible connector

    Read more
  • Impeller Guards (078C)

    Bright Zinc plated Steel or glavanised. Fix with clips & screws (included)

    Read more
  • Matching Flanges (061B)

    Provides easy connection to flexible connector or ducting

    Read more
  • Mounting Feet (060B)

    For free standing mounting of ducted fans

    Read more
  • Silencers (068-D**P)

    Pre-galvanised sheet steel with perforated steel lining

    Read more
  • Av Mounts (Rubber)

    Spring AV mounts - zinc plated steel, rubber insert and foot pad

    Read more
  • Flexible Connectors (063)

    Fits directly to matching flanges providing a flexible connection between the fan and duct or ancilliaries.

    Read more
 

Downloads