PowerPlus SPP
PowerPlus SPP
- 4 standard sizes from 450mm to 630mm.
- Air volume flow rates of up to 3.92 m3/s.
- Static pressures of up to 650 Pa.
- Suitable for operating temperatures up to +70ÅãC.
- Extensive stock range available.
Learn more about DCV
Compare
The PowerPlus SPP range has been specifically developed to tackle higher pressure requirements with a straightforward, efficient and definitive approach. The resilient two stage contra-rotating axial fan is housed in a single robust casing, with both motors wired via a flexible weatherproofed cable system to a single IP55 terminal box mounted on the outside of the casing.
FEATURES & BENEFITSLearn more about individual features and benefits of our products. |
SPECIFICATIONThe Power Plus range of plate mounted axial fans as manufactured by Elta Fans Ltd. |
TECHNICAL INFORMATION |
ACCESSORIESElta supply a full range of accessories for each of their products. |
COMPAREChoose up to three products to compare their features side-by-side. |
DOWNLOADSGet the full brochure, wiring diagrams and operation and maintenance instructions. |
Features & Benefits
Efficient and cost effective
High efficiency impellers coupled with the speed controllable motors through the Eltadrive E2 inverters makes this a very economical method of moving high volumes of air at moderate pressures.
Combined with our dedicated range of Variable Speed Drives, energy consumption can be dramatically reduced during idle periods where ventilation systems can be safely turned down. Lowering the speed of the motor by just 20% can produce an energy saving of up to 50% offering a swift return on your investment.
Quality impeller design.
Comprising Elta Fans tried and trusted adjustable pitch aerofoil section blades. Constructed from high quality pressure die cast aluminium components and factory set at an angle to maximize efficiency and performance for the 2 stage contra rotating impeller assemblies. Dynamically balanced to ISO 14694.
Installer friendly simplicity.
With ease of access for wiring to the externally mounted terminal box, pre-programmed inverters and ex-stock availability the PowerPlus is the ideal choice for installers.
Demand Control
Click on the logo below to learn more about Demand Control Ventilation...
Material strength.
Constructed from robust heavy gauge sheet steel, the roll formed, welded casing includes integral spun flanges for a smoother airflow.
Optimum Choice Availability
The PowerPlus range comprises four standard sizes 450mm, 500mm, 560mm and 630mm diameter. Fully speed controllable for flexibility in performance with an extensive duty range up to 3.92 m³/s.
Outstanding performance
The usage of robust three phase motors, coupled with inverter soft starts, reduces wear and prolongs
Extra Content
The resilient two stage contra-rotating axial fan is housed ina single robust casing, with both motors wired via a flexible weatherproofed cable system to a single IP55 terminal box mounted on the outside of the casing. The feature adds to the installer friendly ethos of the unit ensuring accessiblity and faster wiring of the unit, making it more effortless to handle and install than conventional two staged fans.

Specification
The Power Plus range of high pressure axial fans as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Contact us.
Casing
The all metal fan casing provides a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motors and axial impellers mounted within the length of the unit casing.
All casing parts are heavy gauge mild steel sheet, roll formed and welded for added strength and durability, hot dipped galvanised to BS EN ISO 1461:1999 after fabrication and drilled to BS ISO 6580:2005. The fans are suitable for external mounting as standard.
Motors
Motors are totally enclosed, airstream rated induction motors with sealed for life, maintenance free ball bearings, which allows the fan to be installed at any angle. Each motor is matched to the aerodynamic performance of the impeller. Motors are Class F insulated to EN 60034-5, protected to IP55 and suitable for inverter speed control. Motors are suitable for 230V Delta and 400V Star connection.
Fans are suitable for operating temperatures between -20°C and +70°C. Electrical connection to the motor is provided by an IP55 terminal box which is fitted onto the outer side of the fan casing.
Impellers
Adjustable pitch aerofoil impellers are provided with blades made from high quality die cast aluminium (LM6). Impellers are factory set at an angle to provide maximum performance and efficiency across the duty range. The hubs are manufactured from die cast aluminium alloy (LM24) All impellers are to be dynamically balanced to ISO 14694.
Quality Management
Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001: 2008 PowerPlus units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2: 1985 (sound performance).
Controls Elements
All PowerPlus range of fans are suitable for operation via the Eltadrive range of frequency inverters. The frequency inverters can be controlled by the Elta DCV controller and appropriate
Demand Control
Click on the logo below to learn more about Demand Control Ventilation...

Technical Information
Dimensional Data
| Product Code | A | B | C | D | E | F | G | K | L | M | N | P | Weight kg |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SPP450/4-3 | 450 | 530 | 500 | 285 | 8 | 12 | 500 | 20 | 280 | 255 | 400 | 439 | 42 |
| SPP500/4-3 | 500 | 585 | 550 | 315 | 12 | 12 | 560 | 20 | 315 | 290 | 450 | 489 | 53 |
| SPP560/4-3 | 560 | 645 | 550 | 345 | 12 | 12 | 620 | 20 | 355 | 330 | 510 | 480 | 59 |
| SPP630/4-3 | 630 | 715 | 600 | 380 | 12 | 12 | 690 | 20 | 400 | 375 | 580 | 530 | 83 |
Performance & Electrical Data
THREE Phase - 380V-415V/50Hz
| Product Code | r/min | Airflow/SFP | Airflow m3/s @ Static Pressure Pa. | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0 |
50 |
100 |
150 |
200 |
250 |
300 |
350 |
400 |
450 |
500 |
550 |
600 |
650 |
|||
| SPP450/4-3 | 1410 | m3/s | 1.724 | 1.673 | 1.617 | 1.548 | 1.464 | 1.375 | 1.283 | 1.128 | ||||||
| W/(L/s) | 0.38 | 0.42 | 0.46 | 0.52 | 0.59 | 0.66 | 0.74 | 0.84 | ||||||||
| SPP500/4-3 | 1390 | m3/s | 2.278 | 2.213 | 2.143 | 2.063 | 1.975 | 1.882 | 1.783 | 1.66 | ||||||
| W/(L/s) | 0.41 | 0.45 | 0.5 | 0.55 | 0.61 | 0.67 | 0.74 | 0.82 | ||||||||
| SPP560/4-3 | 1400 | m3/s | 2.846 | 2.758 | 2.672 | 2.586 | 2.496 | 2.398 | 2.286 | 2.148 | 1.949 | 1.587 | 1.258 | 1.01 | ||
| W/(L/s) | 0.41 | 0.47 | 0.52 | 0.57 | 0.62 | 0.67 | 0.73 | 0.8 | 0.9 | 1.1 | 1.36 | 1.69 | ||||
| SPP630/4-3 | 1450 | m3/s | 3.927 | 3.844 | 3.76 | 3.674 | 3.585 | 3.489 | 3.385 | 3.269 | 3.137 | 2.979 | 2.778 | 2.499 | 2.073 | 1.641 |
| W/(L/s) | 0.4 | 0.45 | 0.5 | 0.54 | 0.59 | 0.63 | 0.68 | 0.73 | 0.79 | 0.85 | 0.93 | 1.04 | 1.24 | 1.53 | ||
| Product Code | Input Amps | Output kW | Motor Electrical Data 230V/3/50Hz | Motor Electrical Data 400V/3/50Hz | ||
|---|---|---|---|---|---|---|
| FLC Amps | SC Amps | FLC Amps | SC Amps | |||
| SPP450/4-3 | 4.1 | 0.74 | 3.1 | 14.5 | 2.0 | 9.5 |
| SPP500/4-3 | 5.7 | 1.1 | 4.5 | 20.4 | 2.8 | 13.9 |
| SPP560/4-3 | 7.6 | 1.5 | 5.6 | 26.3 | 3.7 | 19 |
| SPP630/4-3 | 11.6 | 2.2 | 8.7 | 42.1 | 4.8 | 31.2 |
Sound Data
| Product Code | In-Duct Sound Power Level dBW @ Octave Band Hz | dBA @ 3m | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 63Hz | 125Hz | 250Hz | 500Hz | 1 kHz | 2 kHz | 4 kHz | 8 kHz | |||
| SPP450/4-3 | Inlet | 71 | 72 | 81 | 78 | 74 | 70 | 64 | 58 | 59 |
| Outlet | 70 | 72 | 81 | 76 | 75 | 72 | 68 | 61 | 59 | |
| SPP500/4-3 | Inlet | 76 | 76 | 83 | 81 | 79 | 76 | 71 | 64 | 63 |
| Outlet | 77 | 77 | 83 | 80 | 80 | 78 | 74 | 68 | 64 | |
| SPP560/4-3 | Inlet | 81 | 80 | 85 | 84 | 83 | 81 | 77 | 70 | 67 |
| Outlet | 83 | 81 | 85 | 85 | 84 | 83 | 80 | 73 | 69 | |
| SPP630/4-3 | Inlet | 85 | 85 | 89 | 90 | 87 | 85 | 81 | 75 | 72 |
| Outlet | 87 | 85 | 89 | 90 | 88 | 88 | 84 | 79 | 73 | |
Silencer Data
| Product Code | dBA Attenuation | âP (Pa) 1DEP | dBA Attenuation | âP (Pa) 2DEP | ||
|---|---|---|---|---|---|---|
| 1DENP | 1DEP | 2DENP | 2DEP | |||
| SPP450/4-3 | -9 | -12 | 22 | -15 | -18 | 34 |
| SPP500/4-3 | -9 | -14 | 25 | -16 | -20 | 40 |
| SPP560/4-3 | -10 | -15 | 22 | -16 | -22 | 35 |
| SPP630/4-3 | -9 | -16 | 27 | -14 | -25 | 44 |
Wiring Data
| Product Code | Wiring Diagram No. |
|---|---|
| SPP450/4-3 | 152-600 |
| SPP500/4-3 | 152-600 |
| SPP560/4-3 | 152-600 |
| SPP630/4-3 | 152-600 |
Accessories
Bell Mouth inlets (241B)
Fits directly to the fan case flange and provides easy connection to flexible connector
Read more
Impeller Guards (078C)
Bright Zinc plated Steel or glavanised. Fix with clips & screws (included)
Read more
Matching Flanges (061B)
Provides easy connection to flexible connector or ducting
Read more
Mounting Feet (060B)
For free standing mounting of ducted fans
Read more
Silencers (068-D**P)
Pre-galvanised sheet steel with perforated steel lining
Read more
Non-Return Dampers (019)
Prevents reverse flow of air when fan not operating
Read more
Av Mounts (Rubber)
Spring AV mounts - zinc plated steel, rubber insert and foot pad
Read more
Flexible Connectors (063)
Fits directly to matching flanges providing a flexible connection between the fan and duct or ancilliaries.
Read more
DCV Sensors
Demand Control Ventilation
Read more
Electronic Voltage Controller
Electronic Voltage Controller
Read more



Return to 