QUBe SQU
QUBe SQU
- 4 physical sizes with 5 models from 315mm to 710mm.
- Air volume flow rates of up to 3.9 m3/s.
- Static pressures of up to 928 Pa.
- Suitable for operating temperatures up to +50°C.
- Interchangeable double skinned panels.
Learn more about DCV
Compare
The QUBe SQU is a multi-discharge, double skinned fan unit incorporating the high performance backward curved Ziehl-Abegg RH-C impeller designed specifically for operation without a scroll. Supplied for straight through airflow with the outlet panel positioned directly opposite the inlet panel, but the outlet panel can be easily exchanged on-site to provide 90° airflow if required.
FEATURES & BENEFITSLearn more about individual features and benefits of our products. |
SPECIFICATIONThe Qube range of centrifugal fans as manufactured by Elta Fans Ltd. |
TECHNICAL INFORMATIONThe technical information available to you from ELTA Fans is exhaustive - Choose from either sound, performance and electrical or dimensional data for each and every product |
ACCESSORIESElta supply a full range of accessories for each of their products. |
COMPAREChoose up to three products to compare their features side-by-side. |
DOWNLOADSGet the full brochure, wiring diagrams and operation and maintenance instructions. |
Features & Benefits
Material strength
Self supporting corrosion-resistant extruded Aluminium section, assembled with shock resistant fibreglass reinforced Polyamide PA6 corners ideally suited for general ventilation applications.
Motor performance
Three phase multi-voltage IP55 TEFC motor, wound for either (Delta) 230V/3Ph/50Hz or (Star) 400V/3Ph/50Hz connection, which is mounted using a unique low loss X-frame internal mounting arrangement, improving performance, and reducing noise generation, suitable for speed control with the Eltadrive VSD range of frequency inverter controls.
Motors are pre-wired to an IP55 terminal box mounted on the side, for easy customer connection.
Quality Impeller Design
High efficiency backward curved impellers with non-overloading power characteristics.
Choice
Straight through airflow as supplied. Discharge position can be altered on site.
Quality assurance
All QUBe units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2: 1985 (sound performance).
Ease of installation
All models are designed for direct connection to standard diameter flexible or rigid circular ducting with 50mm long spigots for ease of connection. Each spigot has an integral E PDM (Ethylene Propylene), UV + Ozone stable and resistant rubber seal which has a U shaped profile.
Full accessory range
Flexible connectors, attenuators, Eltadrive VSD frequency inverter controls, Eltadrive VSD frequency inverters (1Ph and 3Ph supply).

Specification
The Qube range of centrifugal box fans as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Visit demandcontrolventilation.com. Or contact us.
Casing
Constructed from self supporting corrosion-resistant extruded Aluminium section, assembled with shock resistant fibreglass reinforced Polyamide PA6 corners, and 25mm thick Double skinned fully inter-changeable removable panels, manufactured from pre-galvanised steel, in-filled with a non flammable mineral wool, 60kg/m3, thereby minimising breakout noise.
Motors
Three phase multi-voltage IP55 TEFC Foot / Flange mounted IEC frame motors, wound for either (Delta) 230V/3Ph/50Hz or (Star) at 400V/3Ph/50Hz connection, suitable for speed control when used with the Eltadrive VSD range of frequency inverter controls.
Motors are pre-wired to an IP55 terminal box mounted on the side, for easy customer connection.
Impellers
A high efficiency backward curved welded steel impeller with a non-overloading power characteristic, finished with a powder coating to RAL 5002 for greater surface protection, and dynamically balanced to G2.5 / G6.3 according to ISO1940 part 1.
Quality Management
Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001: 2008. All QUBe units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2: 1985 (sound performance).

Technical Information
Dimensional Data
| Product Code | Spigot ∅ | A | D |
Weight kg |
|---|---|---|---|---|
| SQU1/4 | 315 | 500 | 60 | 38 |
| SQU2/4 | 500 | 670 | 70 | 66 |
| SQU3/4 | 560 | 820 | 70 | 99 |
| SQU4/4 | 710 | 1020 | 85 | 165 |
| SQU4/6 | 710 | 1020 | 85 | 178 |
All dimensions are expressed in mm.
Technical Data
THREE Phase - 380V-415V / 50Hz
| Product Code | Speed r/min | Airflow SFP | Airflow m³/s @ Static Pressure Pa. | Overall Efficiency % | FMEG | Motor Electrical Data | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0 | 100 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 550 | 600 | 700 | 800 | 900 | FLC Amps (Δ) | FLC Amps (Y) | Output kW | |||||
| SQU1/4-3 | 1450 | m³/s | 0.58 | 0.48 | 0.35 | 0.26 | 0.16 |
33.6 |
N50 |
1.4 |
0.8 |
0.25 |
|||||||||
|
W/(L/s) |
0.32 |
0.45 |
0.74 |
1.00 |
1.31 |
||||||||||||||||
|
SQU2/4-3 |
1420 |
m³/s |
1.36 |
1.24 |
1.11 |
1.04 |
0.96 |
0.87 |
0.76 |
0.60 |
0.18 |
54.1 |
N66 |
2.5 |
1.4 |
0.55 |
|||||
|
W/(L/s) |
0.31 |
0.42 |
0.53 |
0.59 |
0.66 |
0.74 |
0.84 |
1.01 |
- |
||||||||||||
|
SQU3/4-3 |
1460 |
m³/s |
1.96 |
1.82 |
1.65 |
1.56 |
1.45 |
1.32 |
1.19 |
1.05 |
0.90 |
0.72 |
0.41 |
50.0 |
N60 |
4.5 |
2.6 |
1.1 |
|||
|
W/(L/s) |
0.39 |
0.49 |
0.60 |
0.66 |
0.73 |
0.81 |
0.90 |
1.01 |
1.13 |
1.30 |
1.86 |
||||||||||
|
SQU4/4-3 |
1450 |
m³/s |
3.87 |
3.64 |
3.42 |
3.31 |
3.21 |
3.10 |
2.98 |
2.87 |
2.74 |
2.61 |
2.47 |
2.14 |
1.70 |
1.08 |
56.8 |
N62 |
11.3 |
7.5 |
3.0 |
|
W/(L/s) |
0.49 |
0.61 |
0.71 |
0.77 |
0.82 |
0.87 |
0.93 |
0.98 |
1.04 |
1.11 |
1.18 |
1.25 |
1.34 |
1.45 |
|||||||
|
SQU4/6-3 |
960 |
m³/s |
3.01 |
2.86 |
2.67 |
2.55 |
2.42 |
2.25 |
2.04 |
1.77 |
1.38 |
67.2 |
N76 |
6.7 |
3.9 |
1.5 |
|||||
|
W/(L/s) |
0.36 |
0.41 |
0.47 |
0.51 |
0.55 |
0.60 |
0.67 |
0.76 |
0.90 |
||||||||||||
FLC (Δ) at 230V/3Ph/50Hz.
FLC (Y) at 400V/3Ph/50Hz.
Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D.
A variable speed drive (Eltadrive) must be installed with this fan.
Sound Data
| Product Code | Sound Power Level dBW @ Octave Band Hz | dBA @ 3m | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 63Hz | 125Hz | 250Hz | 500Hz | 1 k Hz | 2 kHz | 4 kHz | 8 kHz | |||
| SQU1/4-3 | Inlet | 62 | 66 | 70 | 70 | 66 | 62 | 57 | 53 | 51 |
| Outlet | 64 | 68 | 72 | 72 | 68 | 64 | 59 | 55 | 53 | |
| Breakout | 61 | 63 | 61 | 55 | 45 | 35 | 24 | 18 | 36 | |
| SQU2/4-3 | Inlet | 68 | 72 | 76 | 76 | 72 | 68 | 63 | 59 | 57 |
| Outlet | 70 | 74 | 78 | 78 | 74 | 70 | 65 | 61 | 59 | |
| Breakout | 67 | 69 | 67 | 61 | 51 | 41 | 30 | 24 | 42 | |
| SQU3/4-3 | Inlet | 72 | 76 | 79 | 79 | 75 | 71 | 67 | 62 | 60 |
| Outlet | 74 | 78 | 81 | 81 | 77 | 73 | 69 | 64 | 62 | |
| Breakout | 71 | 73 | 70 | 64 | 54 | 44 | 34 | 27 | 45 | |
| SQU4/4-3 | Inlet | 78 | 82 | 86 | 85 | 81 | 77 | 73 | 68 | 66 |
| Outlet | 80 | 84 | 88 | 87 | 83 | 79 | 75 | 70 | 68 | |
| Breakout | 77 | 79 | 77 | 70 | 60 | 50 | 40 | 33 | 51 | |
| SQU4/6-3 | Inlet | 73 | 76 | 79 | 78 | 74 | 70 | 65 | 61 | 59 |
| Outlet | 75 | 78 | 81 | 80 | 76 | 72 | 67 | 63 | 61 | |
| Breakout | 72 | 73 | 70 | 63 | 53 | 43 | 32 | 26 | 44 | |
Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The In-Duct Sound Power Level Spectra are in dB re-1pW.
The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20μPa and is presented for comparative purposes only.
Silencer Data
| Product Code | dBA Attenuation | ΔP (Pa) 1DEP | dBA Attenuation | ΔP (Pa) 2DEP | ||
|---|---|---|---|---|---|---|
| 1DENP | 1DEP | 2DENP | 2DEP | |||
| SQU1/4 | -10 | -13 | 7 | -17 | -20 | 11 |
| SQU2/4 | -10 | -13 | 7 | -17 | -20 | 11 |
| SQU3/4 | -10 | -13 | 8 | -16 | -20 | 13 |
| SQU4/4 | -11 | -15 | 12 | -16 | -23 | 20 |
| SQU4/6 | -11 | -15 | 10 | -16 | -23 | 16 |
Wiring Data
THREE Phase - 380V-415V / 50Hz
| Product Code | Wiring Diagram No. |
|---|---|
| SQU1/4 | 152-611 |
| SQU2/4 | 152-611 |
| SQU3/4 | 152-611 |
| SQU4/4 | 152-611 |
| SQU4/6 | 152-611 |
Accessories
Inverter: IP20
This rating means this unit has a protection level of two against solid-body ingress, and a protection level of zero against the ingress of water.
Read more
Inverter: IP55
This rating means this unit has a protection level of five against solid-body ingress, and a protection level of five against the ingress of water.
Read more
Matching Flanges (061B)
Provides easy connection to flexible connector or ducting
Read more
Silencers (068-D**P)
Pre-galvanised sheet steel with perforated steel lining
Read more
DCV Sensors
Demand Control Ventilation
Read more



Return to