Quietflow SQS
Quietflow SQS

Quietflow SQS

Left Arrow Return to Centrifugal
Left Arrow Return to Products

Quietflow SQS

samf main
 

The Quietflow SQS...EC incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of acoustically treated single in-line fans are suitable for internal mounting, manufactured in galvanised steel with a natural finish.

samf f&b_box

FEATURES & BENEFITS

Learn more about individual features and benefits of our products.

samf spec_box

SPECIFICATION

The Quietflow SQS range of centrifugal fans as manufactured by Elta Fans Ltd.

Technical information

TECHNICAL INFORMATION

The technical information available to you from ELTA Fans is exhaustive - Choose from either sound, performance and electrical or dimensional data for each and every product

Accessories

ACCESSORIES

Elta supply a full range of accessories for each of their products.

Compare

COMPARE

Choose up to three products to compare their features side-by-side.

Downloads

DOWNLOADS

Get the full brochure, wiring diagrams and operation and maintenance instructions.

SPP Features and Benefits
 

Features & Benefits


Design Appeal

Ideal for roof spaces and / or where space is at a premium.

Low Noise

Each unit is acoustically lined, therefore the breakout noise levels are low.

Ease of Installation

All models are designed for direct connection to standard diameter flexible or rigid circular ducting with 50 mm long spigots with EPDM rubber U shaped seals for ease of connection.

Performance

High efficiency low tonal noise backward curved centrifugal impellers are directly driven by an AC or EC external rotor motor, designed to be non overloading and provide high performance characteristics. 

Easy Maintenance

Access to the fan and motor is by an easily removable panel for maintenance when required. 

Material Strength

A robust, yet lightweight unit with a galvanised sheet steel casing treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating

Reliability

Motor and Impeller manufactured by Ziehl-Abegg providing increased reliability.

Mounting

Each unit is supplied with integral mounting brackets.

Motor Protection

All SQS units have integral thermal overload protection which prevents the motor from overheating.

Tested To The Very Latest Standards

SQS units are tested to ISO 5801:1997 (airside performance) and to BS 848 Pt 2:1985 (sound performance) at Elta Fans own test facility, meaning accurate, up to date information on performance and noise data that can be relied upon.

Quality Assurance

All units are designed and manufactured with procedures as defined in BS EN ISO 9001: 2008.

Full Accessory Range

Speed controllers, fast clamps, anti-vibration mounts, electric heater batteries, silencers, panel filters, flexible connectors and non return dampers.

 

 

SPP Specifications

Specification

The Quietflow SQS range of in-line single fans as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Contact us.


Casing

The robust 1.2mm galvanised mild steel sheet casing, is treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating. The wrap around folded casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings.

Each casing provides a suitably sized circular spigot to suit the duct size required. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached.

A removable lid is provided as a standard feature to facilitate ease of maintenance and cleaning.

Motors

The single range of units may have either an EC or AC single rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size

Manufactured by Ziehl-Abegg providing increased reliability

All motors are suitable for use in ambient air conditions up to +60°C.

Impellers

High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to Grade 6.3 and directly driven by the motor to provide a smooth airflow through the unit.

Quality Management

All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. They are also tested in accordance with BS848 Part 2 1985 (sound performance) and ISO 5801:2007 (airside performance).

tech-ad

Technical Information


Dimensional Data

Product  
Code
ABCDEFGHWeight kg
SQS100 509 350 261 100 390 485 375 587 13.4
SQS125 509 350 261 125 390 485 375 587 13.4
SQS150 509 350 261 150 390 485 375 587 13.4
SQS200 548 396 303 200 436 550 421 662 17
SQS250 548 396 333 250 436 550 421 702 18.6
SQS315 635 485 400 315 525 580 510 753 28
SQS400 700 570 472 400 670 580 620 858 39
SQS500 880 750 601 500 850 700 800 1038 60
sqs-dims-1

All dimensions are expressed in mm.

 

 
 

Performance & Electrical

SINGLE Phase - 200V-277V / 50Hz / 60Hz

EC Motors

Product CodeSpeed r/minAirflow SFPAirflow m³/s @ Static Pressure Pa.Overall Efficiency%FMEGMotor Electrical Data
0 25 50 75 100 150 200 250 300 350 400 500 FLC Amps Input kW
SQS100-1ECL 3492 m³/s 0.112 0.11 0.107 0.105 0.103 0.098 0.093 0.088 0.081 0.075 0.067 0.046 30.2 N50 1.19 0.128
W/(L/s) 1.13 1.15 1.18 1.2 1.23 1.28 1.34 1.41 1.49 1.58 1.7 2.1
SQS125-1ECL 3428 m³/s 0.14 0.137 0.134 0.131 0.127 0.121 0.114 0.106 0.098 0.088 0.078 0.051 31.2 N51 1.23 0.133
W/(L/s) 0.93 0.96 0.98 1 1.03 1.08 1.14 1.22 1.31 1.42 1.57 2.15
SQS150-1ECL 3486 m³/s 0.166 0.161 0.157 0.153 0.149 0.14 0.132 0.124 0.116 0.107 0.097 0.073 37.7 N57 1.21 0.141
W/(L/s) 0.85 0.87 0.89 0.91 0.93 0.98 1.03 1.08 1.14 1.21 1.3 1.59
SQS200-1ECL 3404 m³/s 0.31 0.3 0.29 0.28 0.28 0.26 0.25 0.23 0.22 0.2 0.18 0.15 37.7 N54 2.08 0.239
W/(L/s) 0.71 0.73 0.76 0.78 0.81 0.87 0.93 1.01 1.08 1.17 1.28 1.55
SQS250-1ECL 2330 m³/s 0.34 0.33 0.31 0.3 0.28 0.26 0.23 0.2 0.17 0.15 0.13 0.1 32.8 N51 1.87 0.224
W/(L/s) 0.54 0.57 0.59 0.61 0.64 0.7 0.79 0.91 1.07 1.26 1.49 2.02
SQS315 -1ECL 2013 m³/s 0.62 0.61 0.6 0.58 0.57 0.53 0.5 0.46 0.41 0.36 0.3 0.15 35.4 N50 2.07 0.445
W/(L/s) 0.67 0.7 0.72 0.74 0.77 0.82 0.89 0.96 1.04 1.15 1.29 1.97
SQS400-1ECL 2200 m³/s 1.05 1.04 1.03 1.02 1.01 0.98 0.96 0.93 0.9 0.87 0.83 0.72 44.3 N55 4.39 0.954
W/(L/s) 0.76 0.77 0.79 0.8 0.82 0.86 0.89 0.94 0.98 1.04 1.1 1.28
SQS500-1ECL 1422 m³/s 1.42 1.39 1.37 1.34 1.31 1.26 1.19 1.12 1.05 0.96 0.86 0.59 50.9 N62 3.51 0.774
W/(L/s) 0.46 0.48 0.5 0.52 0.53 0.57 0.62 0.67 0.73 0.8 0.89 1.19

Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC @ 230V / 50Hz. A variable speed drive is integrated within the fan.

THREE Phase - 380V-480V / 50Hz / 60Hz

EC Motors

Product CodeSpeed r/minAirflow SFPAirflow m³/s @ Static Pressure Pa.Overall Efficiency%FMEGMotor Electrical Data
0 25 50 75 100 150 200 250 300 350 400 500 FLC Amps Input kW
SQS500-3ECL 1799 m³/s 1.79 1.77 1.75 1.73 1.71 1.67 1.63 1.58 1.54 1.49 1.43 1.31 52.4 N61 2.31 1.5

Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC @ 400V / 50Hz. A variable speed drive is integrated within the fan.

SINGLE Phase - 220V-240V / 50Hz

AC Motors

Product CodeSpeed r/minAirflow SFPAirflow m³/s @ Static Pressure Pa.Overall Efficiency%FMEGMotor Electrical Data
0 25 50 75 100 150 200 250 300 350 400 500 FLC Amps Input kW
SQS100-1ACL 2545 m³/s 0.081 0.078 0.076 0.073 0.07 0.062 0.051 0.039 0.025 09 19.6 N42 0.34 0.063
W/(L/s) 0.79 0.81 0.83 0.86 0.9 0.99 1.16 1.45 2.08 5.5
SQS125-1ACL 2526 m³/s 0.101 0.096 0.092 0.087 0.082 0.071 0.059 0.045 0.027 05 20.7 N43 0.35 0.065
W/(L/s) 0.65 0.68 0.71 0.74 0.78 0.89 1.04 1.31 1.99 8.87
SQS150-1ACL 2515 m³/s 0.13 0.122 0.114 0.106 0.099 0.084 0.069 0.052 0.031 07 22.6 N45 0.35 0.066
W/(L/s) 0.47 0.51 0.56 0.61 0.66 0.77 0.93 1.18 1.79 6.85
SQS200-1ACL 2504 m³/s 0.24 0.23 0.22 0.21 0.19 0.17 0.15 0.13 0.11 0.08 0.06 24.5 N44 0.66 0.141
W/(L/s) 0.56 0.6 0.64 0.68 0.72 0.82 0.93 1.07 1.26 1.53 2.03
SQS250-1ACL 2449 m³/s 0.34 0.33 0.32 0.31 0.3 0.27 0.24 0.21 0.18 0.15 0.13 0.08 26.4 N44 0.99 0.217
W/(L/s) 0.59 0.62 0.64 0.67 0.71 0.79 0.89 1.02 1.18 1.35 1.57 2.33
SQS315 -1ACL 1289 m³/s 0.39 0.38 0.36 0.33 0.3 0.22 0.13 0.05 19.7 N38 0.84 0.179
W/(L/s) 0.45 0.47 0.5 0.54 0.59 0.79 1.22 2.75
SQS400-1ACL 1378 m³/s 0.68 0.66 0.64 0.62 0.59 0.54 0.46 0.36 0.23 0.09 34.2 N50 1.5 0.293
W/(L/s) 0.37 0.39 0.42 0.44 0.47 0.54 0.62 0.75 1.04 2.15
SQS500-1ACL 1216 m³/s 1.24 1.21 1.18 1.15 1.11 1.03 0.94 0.83 0.71 0.58 0.45 0.17 34.5 N47 2.97 0.642
W/(L/s) 0.47 0.49 0.51 0.53 0.55 0.61 0.68 0.77 0.89 1.05 1.28 2.69

Overall total efficiency, r/min and FMEG values are as per ISO 12759 installation category D.

Sound Data

SINGLE Phase - 200V-277V / 50Hz / 60Hz

EC Motors

Product  
Code 
Sound Power Level dBW @ Octave Band HzdBA @ 3m
63Hz 125Hz 250Hz 500Hz 1 k Hz 2 kHz 4 kHz 8 kHz
SQS100-1ECL Inlet 75 75 79 69 54 50 44 44 51
Outlet 83 80 76 67 57 51 43 39 50
Breakout 62 70 70 62 57 51 48 47 44
SQS125-1ECL Inlet 82 77 77 62 53 49 44 44 49
Outlet 84 77 81 72 55 51 42 40 54
Breakout 60 70 67 60 57 51 47 46 43
SQS150-1ECL Inlet 89 74 75 65 56 52 48 47 49
Outlet 83 77 79 68 56 54 50 48 51
Breakout 66 64 66 62 57 52 47 44 43
SQS200-1ECL Inlet 80 79 78 67 60 54 52 52 51
Outlet 90 81 80 68 58 55 51 48 53
Breakout 63 67 68 62 58 53 48 45 44
SQS250-1ECL Inlet 78 76 77 64 55 50 49 47 49
Outlet 80 76 75 64 55 54 49 44 48
Breakout 59 65 71 60 55 49 43 41 44
SQS315 -1ECL Inlet 78 77 83 63 50 52 48 47 54
Outlet 80 77 81 67 60 52 47 44 53
Breakout 68 70 76 64 58 53 47 46 48
SQS400-1ECL Inlet 81 80 83 69 61 58 56 57 55
Outlet 83 79 82 75 68 62 56 52 56
Breakout 72 73 78 70 65 60 51 50 52
SQS500-1ECL Inlet 77 76 67 62 57 54 51 51 45
Outlet 77 80 71 64 58 51 46 42 47
Breakout 74 80 74 66 60 54 48 44 49

Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The In-Duct Sound Power Level Spectra are in dB re-1pW.
The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.

THREE Phase - 380V-480V / 50Hz / 60Hz

EC Motors

Product  
Code 
Sound Power Level dBW @ Octave Band HzdBA @ 3m
63Hz 125Hz 250Hz 500Hz 1 k Hz 2 kHz 4 kHz 8 kHz
SQS500-3ECL Inlet 81 80 75 68 63 62 60 53 51
Outlet 82 84 85 71 66 61 58 47 57
Breakout 80 82 83 75 69 63 57 53 57

SINGLE Phase - 220V-240V / 50Hz

AC Motors

Product  
Code 
Sound Power Level dBW @ Octave Band HzdBA @ 3m
63Hz 125Hz 250Hz 500Hz 1 k Hz 2 kHz 4 kHz 8 kHz
SQS100-1ACL Inlet 68 71 71 53 46 40 39 32 43
Outlet 76 74 72 60 49 41 41 31 45
Breakout 56 68 66 51 48 43 41 39 39
SQS125-1ACL Inlet 69 71 74 54 47 41 38 36 45
Outlet 75 69 73 59 48 43 41 33 45
Breakout 53 61 65 52 51 43 38 34 38
SQS150-1ACL Inlet 67 65 80 53 48 42 40 39 51
Outlet 77 68 81 60 49 44 43 35 52
Breakout 53 57 67 53 50 43 38 35 39
SQS200-1ACL Inlet 73 73 76 59 52 46 44 41 47
Outlet 77 75 74 61 52 49 43 38 46
Breakout 58 64 68 57 53 50 46 43 41
SQS250-1ACL Inlet 74 77 79 62 53 49 46 44 50
Outlet 75 73 78 62 53 50 45 40 49
Breakout 61 68 70 59 53 47 41 39 43
SQS315 -1ACL Inlet 69 76 61 50 38 39 37 29 40
Outlet 70 75 61 52 47 37 34 27 40
Breakout 58 64 57 51 45 38 32 27 33
SQS400-1ACL Inlet 72 78 65 55 48 45 43 41 43
Outlet 75 75 65 60 52 43 39 35 42
Breakout 65 70 64 57 50 44 39 37 39
SQS500-1ACL Inlet 74 74 63 58 52 50 46 49 42
Outlet 74 74 67 60 53 47 41 39 43
Breakout 75 80 69 64 55 47 40 38 47

Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The In-Duct Sound Power Level Spectra are in dB re-1pW.
The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.

Silencer Data

SINGLE Phase - 200V-277V / 50Hz / 60Hz

EC Motors

Product  
Code 
dBA Attenuation
300L 600L 900L 1200L
SQS100-1ECL Inlet -10 -15 -21 -23
Outlet -8 -12 -17 -19
SQS125-1ECL Inlet -7 -11 -16 -19
Outlet -9 -13 -18 -21
SQS150-1ECL Inlet -6 -9 -12 -15
Outlet -7 -12 -15 -17
SQS200-1ECL Inlet -6 -10 -14 -17
Outlet -5 -9 -12 -15
SQS250-1ECL Inlet -6 -10 -12 -14
Outlet -6 -10 -12 -14
SQS315-1ECL Inlet -6 -8 -10 -14
Outlet -6 -8 -10 -14
SQS400-1ECL Inlet -5 -7 -9 -13
Outlet -6 -9 -11 -15

SINGLE Phase - 220V-240V / 50Hz

AC Motors

Product  
Code 
dBA Attenuation
300L 600L 900L 1200L
SQS100-1ACL Inlet -8 -13 -18 -20
Outlet -8 -12 -18 -20
SQS125-1ACL Inlet -7 -12 -17 -20
Outlet -8 -12 -17 -20
SQS150-1ACL Inlet -6 -12 -15 -17
Outlet -6 -12 -15 -17
SQS200-1ACL Inlet -6 -10 -14 -17
Outlet -6 -9 -13 -16
SQS250-1ACL Inlet -6 -10 -12 -14
Outlet -6 -10 -12 -15
SQS315-1ACL Inlet -3 -5 -7 -10
Outlet -4 -6 -8 -10
SQS400-1ACL Inlet -3 -5 -7 -9
Outlet -4 -6 -8 -11

SINGLE Phase - 200V-277V / 50Hz / 60Hz

EC Motors

Product  
Code 
dBA Attenuation
1DENP 2DENP
SQS500-1ECL Inlet -7 -11
Outlet -6 -10

THREE Phase - 380V-480V / 50Hz / 60Hz

EC Motors

Product  
Code  
dBA Attenuation
1DENP 2DENP
SQS500-3ECL Inlet -7 -12
Outlet -6 -12

SINGLE Phase - 220V-240V / 50Hz

AC Motors

Product  
Code
Wiring
Diagram No.
SH100-1ECL 152-00036
SH125-1ECL 152-00036
SH150-1ECL 152-00036
SH200-1ECL 152-00036
SH250-1ECL 152-00036
SH315-1ECL 152-00036

Accessories

  • Fast Clamps (018)

    For quick connection of spigotted fans to circular duct or accessories

    Read more
  • Silencers (068-JF)

    Pre-galvanised sheet steel with perforated steel lining

    Read more
  • Silencers (068-D**P)

    Pre-galvanised sheet steel with perforated steel lining

    Read more
  • Av Mounts (Rubber)

    Spring AV mounts - zinc plated steel, rubber insert and foot pad

    Read more
  • Flexible Connectors (018)

    Read more
  • Panel Filters (018)

    Filter access with removable panel

    Read more
  • Electric Heater Batteries

    Safe and clean heating

    Read more
  • Electronic Voltage Controller

    Electronic Voltage Controller

    Read more
 

Downloads