The Quietflow SQT DCV...ECL incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of acoustically treated in-line centrifugal twin fans are suitable for Demand Control Ventilation via matching sensors.

sqte fb box

FEATURES & BENEFITS

Learn more about individual features and benefits of our products.

samf spec_box

SPECIFICATION

The Quietflow SQT DCV range of centrifugal fans as manufactured by Elta Fans Ltd.

Technical information

TECHNICAL INFORMATION

The technical information available to you from ELTA Fans is exhaustive - Choose from either sound, performance and electrical or dimensional data for each and every product

Accessories

ACCESSORIES

Elta supply a full range of accessories for each of their products.

Compare

COMPARE

Choose up to three products to compare their features side-by-side.

Downloads

DOWNLOADS

Get the full brochure, wiring diagrams and operation and maintenance instructions.

sqsdcv fb ad1
 

Features & Benefits


Design Appeal

Ideal for roof spaces and / or where space is at a premium.

Low Noise.

Each unit is acoustically lined, therefore the breakout noise levels are low.

Ease Of Installation

All models are designed for direct connection to standard diameter flexible or rigid circular ducting with 50 mm long spigots with EPDM rubber U shaped seals for ease of connection.

Performance 

High efficiency backward curved centrifugal impellers are directly driven by an AC or EC external rotor motor, designed to be non overloading and provide high performance characteristics. SQTDCV units are fitted with a non return damper for elimination of short circuiting of air within the casing.

Easy Maintenance

Access to the fan and motor is by an easily removable panel for maintenance when required.

Material Strength

A robust, yet lightweight unit with a galvanised sheet steel casing treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating.

Reliability

Motors and Impellers manufactured by Ziehl-Abegg providing increased reliability.

Mounting

Each unit is supplied with integral mounting brackets.

Motor Protection

All SQTDCV units have integral thermal overload protection which prevents the motor from overheating.

Tested To The Very Latest Standards

SQTDCV units are tested to ISO 5801:2007 (airside performance) and to BS 848 Pt 2:1985 (sound performance) at Elta Fans own test facility, meaning accurate, up to date information on performance and noise data that can be relied upon.

Demand Control

All units supplied with integral controls to provide automated ventilation based on customer requirements complete with remote human interface.
Click on the logo below to learn more about Demand Control Ventilation...

Quality Assurance

All units are designed and manufactured with procedures as defined in BS EN ISO 9001: 2008.

Warranty

Each SQTDCV has a 12 month warranty.

Full Accessory Range Of Accessories

Fast clamps, anti-vibration mounts, silencers, panel filters, and flexible connectors.






SPP Specifications

Specification

The Quietflow DCV range of in-line twin fans as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Visit demandcontrolventilation.com. Or contact us.


Casing

The robust 1.2mm galvanised mild steel sheet casing, is treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating. The wrap around folded casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings.

Each casing provides spigots to suit standard circular ducting. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. A removable lid is provided as a standard feature to facilitate ease of maintenance and cleaning.


Impellers

High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to ISO 14694 Grade G6.3 and directly driven by the motor to provide a smooth airflow through the unit.


Motors

The twin range of units may have either an EC or AC twin rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size.

Manufactured by Ziehl-Abegg providing increased reliability. All motors are suitable for use in ambient air conditions up to +60°C. The twin range of units incorporate automatic control interface for easy connection to Building Management Systems to control and monitor performance. Electrical connection shall be via an IP55 terminal box mounted on the side for easy customer connection.


Quality Management

Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001:2008. All SQT DCV units are to be tested to ISO 5801:2007 (airside performance) and BS 848 Part 2:1985 (sound performance).


Typical Application

  • Toilets and Bathrooms
  • Hotels
  • Kitchens
  • Residential
  • Offices
  • Libraries
tech-ad

Technical Information

ACEC

Dimensional Data

SQS-DCV1

























Quietflow-SQT-DCV-DimTable

All dimensions are expressed in mm.

Performance & Electrical Data

Quietflow-SQT-DCV-PE-SinglePh-AC


Quietflow-SQT-DCV-PE2-SinglePh-AC

Quietflow-SQT-DCV-PE-SinglePh-EC

Quietflow-SQT-DCV-PE2-SinglePh-EC

Quietflow-SQT-DCV-PE-ThreePh-EC

Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC @ 400V / 50Hz. A variable speed drive is integrated within the fan.

 

Sound Data

Quietflow-SQT-DCV-Sound-SinglePh-AC

Quietflow-SQT-DCV-Sound2-SinglePh-AC

* At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible. (less than 20dBA)Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The In-Duct Sound Power Level Spectra are in dB re-1pW. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.

* At 2V the average spherical free-field sound pressure levels cannot be accurately measured above the background level in our conventional laboratory facilities. When correctly installed the fan will be inaudible. (less than 20dBA)Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The In-Duct Sound Power Level Spectra are in dB re-1pW. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.


Quietflow-SQT-DCV-Sound-SinglePh-EC

Quietflow-SQT-DCV-Sound2-SinglePh-EC


Quietflow-SQT-DCV-Sound-ThreeePh-EC

Accessories & Wiring Data

Quietflow-SQT-DCV-Accessories-SinglePh-AC

Quietflow-SQT-DCV-Accessories2Wiring-SinglePh-AC

Quietflow-SQT-DCV-Accessories3-SinglePh-AC

Quietflow-SQT-DCV-Accessories-SinglePh-EC

Quietflow-SQT-DCV-Accessories2Wiring-SinglePh-EC


Quietflow-SQT-DCV-Accessories-ThreePh-EC

Quietflow-SQT-DCV-Accessories2Wiring-ThreePh-EC

Quietflow-SQT-DCV-Accessories3-ThreePh-EC

Accessories

  • Fast Clamps (018)

    For quick connection of spigotted fans to circular duct or accessories

    Read more
  • Silencers (068-JF)

    Pre-galvanised sheet steel with perforated steel lining

    Read more
  • Av Mounts (Rubber)

    Spring AV mounts - zinc plated steel, rubber insert and foot pad

    Read more
  • Flexible Connectors (018)

    Read more
  • Panel Filters (018)

    Filter access with removable panel

    Read more
  • Electric Heater Batteries

    Safe and clean heating

    Read more
 

Accessories & Wiring Data

Quietflow-SQT-DCV-Accessories-SinglePh-AC

Quietflow-SQT-DCV-Accessories2Wiring-SinglePh-AC

Quietflow-SQT-DCV-Accessories3-SinglePh-AC

Quietflow-SQT-DCV-Accessories-SinglePh-EC

Quietflow-SQT-DCV-Accessories2Wiring-SinglePh-EC


Quietflow-SQT-DCV-Accessories-ThreePh-EC

Quietflow-SQT-DCV-Accessories2Wiring-ThreePh-EC

Quietflow-SQT-DCV-Accessories3-ThreePh-EC

Downloads