SQT
- 8 standard sizes from 100mm to 500mm.
- Air volume flow rates of up to 1.82 m3/s (EC) and 1.23 m3/s (AC).
- Static pressures of up to 1028 Pa (EC) and 570 Pa (AC).
- Suitable for operating temperatures up to +60°C.
- Extensive stock range available.
Compare
The Quietflow SQT...ECL incorporates the BAT (Best Available Technology) Vpro backward curved impeller, with three dimensional profiled blades powered by the ultra reliable Ziehl-Abegg EC (electronically commutated) external rotor motor. The range of acoustically treated in-line centrifugal twin fans are suitable for internal mounting, manufactured in galvanised steel with a natural finish.
FEATURES & BENEFITSLearn more about individual features and benefits of our products. |
SPECIFICATIONThe Quietflow SQT range of centrifugal fans as manufactured by Elta Fans Ltd. |
TECHNICAL INFORMATIONThe technical information available to you from ELTA Fans is exhaustive - Choose from either sound, performance and electrical or dimensional data for each and every product |
ACCESSORIESElta supply a full range of accessories for each of their products. |
COMPAREChoose up to three products to compare their features side-by-side. |
DOWNLOADSGet the full brochure, wiring diagrams and operation and maintenance instructions. |
Features & Benefits
Design Appeal
Ideal for roof spaces and / or where space is at a premium.
Low Noise
Each unit is acoustically lined, therefore the breakout noise levels are low.
Ease of Installation
All models are designed for direct connection to standard diameter flexible or rigid circular ducting with 50 mm long spigots with EPDM rubber U shaped seals for ease of connection.Performance
High efficiency low tonal noise backward curved centrifugal impellers are directly driven by an AC or EC external rotor motor, designed to be non overloading and provide high performance characteristics.
Easy Maintenance
Top and bottom access to the fan and motor is by an easily removable panel for maintenance when required.
Material Strength
A robust, yet lightweight unit with a galvanised sheet steel casing treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating.
Reliability
Motor and Impeller manufactured by Ziehl-Abegg providing increased reliability.
Mounting
Each unit is supplied with integral mounting brackets.
Motor Protection
All SQT units have integral thermal overload protection which prevents the motor from overheating.
Tested To The Very Latest Standards
SQT units are tested to ISO 5801:2007 (airside performance) and to BS 848 Pt 2:1985 (sound performance) at Elta Fans own test facility, meaning accurate, up to date information on performance and noise data that can be relied upon.
Quality Assurance
All units are designed and manufactured with procedures as defined in BS EN ISO 9001: 2008.
Full Accessory Range
Speed controllers, fast clamps, anti-vibration mounts, silencers, panel filters, flexible connectors and auto-changeover panels.

Specification
The Quietflow SQT range of in-line twin fans as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Contact us.
Casing
The robust 1.2mm galvanised mild steel sheet casing, is treated internally with a Class O rated (BS 476 Parts 6 and 7) fire resistant acoustic foam lining with a fire resistant polymeric coating. The wrap around folded casing is specially manufactured using integral motor mounting plates to provide additional rigidity for the casings. Each casing provides a suitably sized circular spigot to suit the duct size required. EPDM (Ethylene Propylene) rubber U shaped seals (being ozone and UV stable) are used to ensure a good seal back to the duct that is to be attached. A removable lid is provided as a standard feature to facilitate ease of maintenance and cleaning.
The units have been constructed from mild steel, with mounting brackets as an integral component. Both motors and axial impellers mounted within the length of the unit casing.
All casing parts shall have a powder coated finish after manufacture, except the SAMF150/2-2 which has a die cast aluminium housing.
Motors
The twin range of units may have either an EC or AC twin rotor motor fitted as standard. The motor contains sealed for life bearings. Thermal Class of motors to THCL 130 or 155 dependent on size
Manufactured by Ziehl-Abegg providing increased reliability
All motors are suitable for use in ambient air conditions up to +60°C.
Impellers
High efficiency low tonal noise backward curved centrifugal impeller, dynamically balanced to Grade 6.3 and directly driven by the motor to provide a smooth airflow through the unit.
Quality Management
They are also tested in accordance with BS848 Part 2 1985 (sound performance) and ISO 5801:2007 (airside performance).

Technical Infomation
Dimensional Data
| Product Code | A | B | C | D | E | F | G | Weightkg |
|---|---|---|---|---|---|---|---|---|
| SQT100 | 570 | 555 | 265 | 100 | 537 | 575 | 600 | 28 |
| SQT125 | 570 | 555 | 265 | 125 | 537 | 575 | 600 | 28 |
| SQT150 | 570 | 555 | 265 | 150 | 537 | 575 | 600 | 28 |
| SQT200 | 607 | 657 | 305 | 200 | 569 | 667 | 702 | 36 |
| SQT250 | 607 | 657 | 335 | 250 | 569 | 667 | 702 | 39 |
| SQT315 | 755 | 869 | 405 | 315 | 702 | 889 | 914 | 60 |
| SQT400 | 851 | 1024 | 477 | 400 | 700 | 1069 | 1119 | 89 |
| SQT500 | 993 | 1259 | 606 | 500 | 800 | 1304 | 1354 | 128 |
Performance & Electrical Data
SINGLE Phase - 200V-277V / 50Hz / 60Hz
EC Motors
| Product Code | Speed r/min | Airflow SFP | Airflow m³/s @ Static Pressure Pa. | Overall Efficiency % | FMEG | Motor Electrical Data | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0 | 25 | 50 | 75 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | FLC Amps | Input kW | |||||
| SQT100-1ECL | 3467 | m³/s | 0.103 | 0.102 | 0.10 | 0.098 | 0.096 | 0.092 | 0.087 | 0.082 | 0.076 | 0.07 | 0.062 | 0.044 | 24 | N43 | 1.23 | 0.14 |
| W/(L/s) | 1.26 | 1.29 | 1.32 | 1.36 | 1.39 | 1.47 | 1.56 | 1.66 | 1.78 | 1.92 | 2.1 | 2.76 | ||||||
| SQT125-1ECL | 3445 | m³/s | 0.123 | 0.121 | 0.118 | 0.115 | 0.112 | 0.106 | 0.1 | 0.092 | 0.084 | 0.075 | 0.065 | 0.037 | 24.3 | N43 | 1.21 | 0.151 |
| W/(L/s) | 1.16 | 1.18 | 1.2 | 1.22 | 1.25 | 1.31 | 1.38 | 1.47 | 1.59 | 1.76 | 2.01 | 3.39 | ||||||
| SQT150-1ECL | 3450 | m³/s | 0.146 | 0.143 | 0.14 | 0.137 | 0.133 | 0.125 | 0.116 | 0.107 | 0.098 | 0.089 | 0.079 | 0.057 | 28.2 | N47 | 1.17 | 0.134 |
| W/(L/s) | 0.91 | 0.93 | 0.94 | 0.96 | 0.99 | 1.05 | 1.12 | 1.22 | 1.35 | 1.49 | 1.68 | 2.31 | ||||||
| SQT200-1ECL | 3348 | m³/s | 0.274 | 0.267 | 0.261 | 0.254 | 0.248 | 0.235 | 0.221 | 0.208 | 0.194 | 0.179 | 0.164 | 0.13 | 32.8 | N49 | 1.9 | 0.24 |
| W/(L/s) | 0.81 | 0.84 | 0.87 | 0.9 | 0.93 | 0.99 | 1.06 | 1.14 | 1.23 | 1.33 | 1.45 | 1.81 | ||||||
| SQT250-1ECL | 2390 | m³/s | 0.33 | 0.32 | 0.31 | 0.3 | 0.28 | 0.25 | 0.22 | 0.19 | 0.16 | 0.13 | 0.1 | 0.05 | 29.8 | N48 | 1.89 | 0.223 |
| W/(L/s) | 0.58 | 0.6 | 0.62 | 0.65 | 0.67 | 0.75 | 0.85 | 0.99 | 1.19 | 1.48 | 1.97 | 4.18 | ||||||
| SQT315-1ECL | 2011 | m³/s | 0.63 | 0.61 | 0.6 | 0.59 | 0.58 | 0.55 | 0.52 | 0.49 | 0.45 | 0.41 | 0.36 | 0.22 | 42 | N56 | 1.96 | 0.428 |
| W/(L/s) | 0.61 | 0.63 | 0.65 | 0.67 | 0.69 | 0.74 | 0.79 | 0.85 | 0.92 | 0.99 | 1.1 | 1.55 | ||||||
| SQT400-1ECL | 2201 | m³/s | 1.07 | 1.06 | 1.04 | 1.02 | 1 | 0.97 | 0.93 | 0.89 | 0.86 | 0.82 | 0.78 | 0.7 | 46.9 | N57 | 4.25 | 0.914 |
| W/(L/s) | 0.8 | 0.82 | 0.83 | 0.85 | 0.87 | 0.9 | 0.94 | 0.98 | 1.02 | 1.07 | 1.12 | 1.25 | ||||||
| SQT500-1ECL | 1429 | m³/s | 1.45 | 1.42 | 1.39 | 1.36 | 1.33 | 1.25 | 1.17 | 1.09 | 1 | 0.91 | 0.82 | 0.62 | 49.1 | N60 | 3.5 | 0.774 |
| W/(L/s) | 0.49 | 0.5 | 0.52 | 0.53 | 0.55 | 0.6 | 0.65 | 0.7 | 0.77 | 0.84 | 0.92 | 1.17 | ||||||
Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC @ 230V / 50Hz. A variable speed drive is integrated within the fan.
THREE Phase - 380V-480V / 50Hz / 60Hz
EC Motors
| Product Code | Speed r/min | Airflow SFP | Airflow m³/s @ Static Pressure Pa. | Overall Efficiency % | FMEG | Motor Electrical Data | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0 | 25 | 50 | 75 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | FLC Amps | Input kW | |||||
| SQT500-3ECL | 1800 | m³/s | 1.82 | 1.8 | 1.77 | 1.75 | 1.73 | 1.68 | 1.63 | 1.57 | 1.51 | 1.45 | 1.39 | 1.27 | 51.8 | N60 | 2.29 | 1.482 |
| W/(L/s) | 0.76 | 0.77 | 0.79 | 0.8 | 0.82 | 0.85 | 0.88 | 0.92 | 0.97 | 1.01 | 1.06 | 1.17 | ||||||
Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D. FLC @ 230V / 50Hz. A variable speed drive is integrated within the fan.
SINGLE Phase - 220V-240V / 50Hz
AC Motors
| Product Code | Speed r/min | Airflow SFP | Airflow m³/s @ Static Pressure Pa. | Overall Efficiency % | FMEG | Motor Electrical Data | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0 | 25 | 50 | 75 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 500 | FLC Amps | Input kW | |||||
| SQT100-1ACL | 2510 | m³/s | 0.075 | 0.073 | 0.07 | 0.067 | 0.063 | 0.055 | 0.046 | 0.035 | 0.02 | 14.1 | N36 | 0.35 | 0.075 | |||
| W/(L/s) | 1 | 1.03 | 1.07 | 1.12 | 1.17 | 1.33 | 1.56 | 1.99 | 3.39 | |||||||||
| SQT125-1ACL | 2517 | m³/s | 0.09 | 0.09 | 0.09 | 0.08 | 0.08 | 0.07 | 0.06 | 0.04 | 0.02 | 16.7 | N39 | 0.35 | 0.076 | |||
| W/(L/s) | 0.81 | 0.83 | 0.86 | 0.89 | 0.94 | 1.07 | 1.28 | 1.65 | 3.18 | |||||||||
| SQT150-1ACL | 2479 | m³/s | 0.111 | 0.107 | 0.103 | 0.098 | 0.093 | 0.081 | 0.065 | 0.046 | 0.022 | 18.7 | N41 | 0.34 | 0..75 | |||
| W/(L/s) | 0.65 | 0.68 | 0.71 | 0.75 | 0.79 | 0.91 | 1.11 | 1.54 | 2.95 | |||||||||
| SQT200-1ACL | 2543 | m³/s | 0.22 | 0.21 | 0.2 | 0.2 | 0.19 | 0.17 | 0.15 | 0.13 | 0.11 | 0.09 | 0.06 | 22.6 | N41 | 0.68 | 0.155 | |
| W/(L/s) | 0.67 | 0.7 | 0.73 | 0.77 | 0.81 | 0.9 | 1.01 | 1.16 | 1.37 | 1.71 | 2.45 | |||||||
| SQT250-1ACL | 2424 | m³/s | 0.33 | 0.32 | 0.31 | 0.29 | 0.28 | 0.25 | 0.23 | 0.2 | 0.17 | 0.14 | 0.1 | 0.04 | 23.8 | N41 | 0.96 | 0.22 |
| W/(L/s) | 0.64 | 0.66 | 0.69 | 0.72 | 0.76 | 0.85 | 0.96 | 1.1 | 1.29 | 1.56 | 1.97 | 3.94 | ||||||
| SQT315-1ACL | 1263 | m³/s | 0.4 | 0.38 | 0.36 | 0.33 | 0.3 | 0.23 | 0.14 | 0.03 | 22.5 | N41 | 0.75 | 0.159 | ||||
| W/(L/s) | 0.39 | 0.41 | 0.44 | 0.48 | 0.53 | 0.69 | 1.04 | 4.25 | ||||||||||
| SQT400-1ACL | 1379 | m³/s | 0.71 | 0.68 | 0.66 | 0.63 | 0.59 | 0.51 | 0.43 | 0.35 | 0.25 | 0.05 | 31.5 | N47 | 1.48 | 0.299 | ||
| W/(L/s) | 0.38 | 0.39 | 0.42 | 0.44 | 0.48 | 0.56 | 0.67 | 0.81 | 1.09 | 4.6 | ||||||||
| SQT500-1ACL | 1214 | m³/s | 1.23 | 1.19 | 1.14 | 1.09 | 1.05 | 0.95 | 0.85 | 0.74 | 0.63 | 0.5 | 0.36 | 0.05 | 30.5 | N43 | 2.94 | 0.649 |
| W/(L/s) | 0.5 | 0.51 | 0.54 | 0.56 | 0.59 | 0.65 | 0.74 | 0.85 | 1.01 | 1.26 | 1.69 | 11.1 | ||||||
Overall total efficiency, r/min and FMEG values are per ISO 12759 installation category D.
Sound Data
SINGLE Phase - 220V-277V / 50Hz / 60Hz
EC Motors
| Product Code | Sound Power Level dBW @ Octave Band Hz | dBA @ 3m | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 63Hz | 125Hz | 250Hz | 500Hz | 1 kHz | 2 kHz | 4 kHz | 8 kHz | |||
| SQT100-1ECL | Inlet | 75 | 79 | 74 | 68 | 55 | 51 | 45 | 41 | 49 |
| Outlet | 78 | 75 | 72 | 67 | 60 | 51 | 48 | 45 | 48 | |
| Breakout | 59 | 59 | 61 | 58 | 55 | 51 | 45 | 42 | 40 | |
| SQT125-1ECL | Inlet | 82 | 74 | 74 | 71 | 58 | 52 | 47 | 49 | 50 |
| Outlet | 80 | 75 | 78 | 70 | 64 | 53 | 49 | 49 | 52 | |
| Breakout | 54 | 58 | 64 | 62 | 57 | 51 | 43 | 40 | 42 | |
| SQT150-1ECL | Inlet | 85 | 74 | 73 | 71 | 58 | 54 | 51 | 52 | 50 |
| Outlet | 84 | 77 | 75 | 69 | 62 | 54 | 52 | 53 | 50 | |
| Breakout | 59 | 60 | 66 | 63 | 57 | 51 | 46 | 45 | 43 | |
| SQT200-1ECL | Inlet | 80 | 77 | 79 | 75 | 63 | 59 | 56 | 55 | 54 |
| Outlet | 87 | 83 | 79 | 73 | 64 | 58 | 55 | 55 | 54 | |
| Breakout | 63 | 66 | 70 | 69 | 62 | 57 | 50 | 41 | 48 | |
| SQT250-1ECL | Inlet | 78 | 73 | 75 | 70 | 59 | 54 | 53 | 51 | 50 |
| Outlet | 79 | 75 | 77 | 67 | 60 | 57 | 53 | 51 | 50 | |
| Breakout | 60 | 63 | 71 | 63 | 56 | 49 | 42 | 37 | 44 | |
| SQT315-1ECL | Inlet | 75 | 73 | 78 | 69 | 53 | 55 | 50 | 48 | 51 |
| Outlet | 77 | 74 | 77 | 70 | 59 | 55 | 52 | 49 | 51 | |
| Breakout | 66 | 67 | 74 | 65 | 58 | 52 | 46 | 40 | 47 | |
| SQT400-1ECL | Inlet | 81 | 77 | 87 | 71 | 66 | 62 | 59 | 58 | 58 |
| Outlet | 82 | 78 | 80 | 77 | 69 | 65 | 62 | 59 | 57 | |
| Breakout | 73 | 72 | 79 | 71 | 67 | 61 | 54 | 47 | 53 | |
| SQT500-1ECL | Inlet | 77 | 84 | 75 | 64 | 59 | 57 | 53 | 52 | 51 |
| Outlet | 78 | 82 | 73 | 71 | 62 | 57 | 54 | 50 | 51 | |
| Breakout | 73 | 79 | 73 | 69 | 61 | 54 | 47 | 42 | 50 | |
Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The In-Duct Sound Power Level Spectra are in dB re-1pW. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.
THREE Phase - 380V-415V / 50Hz
EC Motors
| Product Code | Sound Power Level dBW @ Octave Band Hz | dBA @ 3m | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 63Hz | 125Hz | 250Hz | 500Hz | 1 k Hz | 2 kHz | 4 kHz | 8 kHz | |||
| SQT500-3ECL | Inlet | 81 | 84 | 86 | 72 | 66 | 65 | 62 | 56 | 58 |
| Outlet | 82 | 83 | 83 | 77 | 69 | 65 | 62 | 56 | 58 | |
| Breakout | 77 | 80 | 81 | 75 | 68 | 61 | 54 | 49 | 56 | |
Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The Sound Power Level Spectra are in dB re-1pW.The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.
SINGLE Phase - 220V-240V / 50Hz
AC Motors
| Product Code | Sound Power Level dBW @ Octave Band Hz | dBA @ 3m | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 63Hz | 125Hz | 250Hz | 500Hz | 1 kHz | 2 kHz | 4 kHz | 8 kHz | |||
| SQT100-1ACL | Inlet | 62 | 68 | 65 | 58 | 46 | 42 | 38 | 33 | 39 |
| Outlet | 72 | 69 | 67 | 59 | 51 | 43 | 38 | 30 | 41 | |
| Breakout | 51 | 54 | 60 | 51 | 48 | 42 | 36 | 29 | 34 | |
| SQT125-1ACL | Inlet | 67 | 68 | 66 | 62 | 48 | 44 | 38 | 37 | 41 |
| Outlet | 74 | 67 | 69 | 58 | 51 | 43 | 40 | 39 | 42 | |
| Breakout | 45 | 54 | 60 | 53 | 51 | 44 | 40 | 37 | 36 | |
| SQT150-1ACL | Inlet | 68 | 65 | 68 | 62 | 50 | 46 | 41 | 39 | 42 |
| Outlet | 76 | 69 | 75 | 59 | 52 | 45 | 43 | 41 | 46 | |
| Breakout | 51 | 53 | 60 | 53 | 49 | 42 | 34 | 26 | 35 | |
| SQT200-1ACL | Inlet | 79 | 72 | 74 | 67 | 55 | 51 | 47 | 44 | 48 |
| Outlet | 77 | 75 | 72 | 68 | 57 | 52 | 49 | 49 | 48 | |
| Breakout | 57 | 62 | 66 | 61 | 55 | 49 | 44 | 41 | 42 | |
| SQT250-1ACL | Inlet | 77 | 73 | 78 | 70 | 59 | 54 | 53 | 53 | 51 |
| Outlet | 77 | 76 | 74 | 68 | 61 | 57 | 53 | 52 | 49 | |
| Breakout | 61 | 63 | 70 | 63 | 57 | 48 | 41 | 38 | 44 | |
| SQT315-1ACL | Inlet | 66 | 74 | 62 | 53 | 42 | 41 | 37 | 28 | 39 |
| Outlet | 69 | 75 | 57 | 57 | 46 | 41 | 37 | 33 | 40 | |
| Breakout | 58 | 69 | 58 | 54 | 47 | 39 | 31 | 26 | 36 | |
| SQT400-1ACL | Inlet | 73 | 76 | 72 | 59 | 49 | 50 | 47 | 40 | 45 |
| Outlet | 75 | 80 | 67 | 63 | 54 | 50 | 48 | 43 | 46 | |
| Breakout | 61 | 68 | 65 | 56 | 50 | 45 | 40 | 35 | 39 | |
| SQT500-1ACL | Inlet | 75 | 78 | 72 | 60 | 54 | 52 | 49 | 49 | 46 |
| Outlet | 75 | 80 | 70 | 67 | 58 | 53 | 50 | 46 | 48 | |
| Breakout | 70 | 76 | 70 | 65 | 58 | 52 | 45 | 41 | 46 | |
Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure. The In-Duct Sound Power Level Spectra are in dB re-1pW. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.
Silencer Data
SINGLE Phase - 200V-277V / 50Hz / 60Hz
EC Motors
| Product Code | dBA Attenuation | ||||
|---|---|---|---|---|---|
| 300L | 600L | 900L | 1200L | ||
| SQT100-1ECL | Inlet | -8 | -13 | -18 | -20 |
| Outlet | -10 | -14 | -20 | -22 | |
| SQT125-1ECL | Inlet | -10 | -14 | -19 | -22 |
| Outlet | -9 | -14 | -19 | -22 | |
| SQT150-1ECL | Inlet | -9 | -13 | -16 | -19 |
| Outlet | -8 | -12 | -15 | -18 | |
| SQT200-1ECL | Inlet | -9 | -13 | -17 | -20 |
| Outlet | -7 | -10 | -14 | -17 | |
| SQT250-1ECL | Inlet | -8 | -12 | -14 | -17 |
| Outlet | -7 | -11 | -13 | -16 | |
| SQT315-1ECL | Inlet | -7 | -9 | -11 | -15 |
| Outlet | -8 | -10 | -12 | -15 | |
| SQT400-1ECL | Inlet | -5 | -8 | -10 | -13 |
| Outlet | -8 | -11 | -13 | -16 | |
SINGLE Phase - 200V-277V / 50Hz / 60Hz
EC Motors
| Product Code | dBA Attenuation | ||
|---|---|---|---|
| 1DENP | 2DENP | ||
| SQT500-1ECL | Inlet | -6 | -10 |
| Outlet | -7 | -12 | |
THREE Phase - 380V-415V / 50Hz
EC Motors
| Product Code | dBA Attenuation | ||
|---|---|---|---|
| 1DENP | 2DENP | ||
| SQT500-3ECL | Inlet | -6 | -12 |
| Outlet | -7 | -13 | |
SINGLE Phase - 220V-240V / 50Hz
AC Motors
| Product Code | dBA Attenuation | ||||
|---|---|---|---|---|---|
| 300L | 600L | 900L | 1200L | ||
| SQT100-ACL | Inlet | -9 | -14 | -19 | -21 |
| Outlet | -9 | -13 | -19 | -21 | |
| SQT125-ACL | Inlet | -9 | -14 | -19 | -22 |
| Outlet | -8 | -12 | -17 | -20 | |
| SQT150-ACL | Inlet | -8 | -14 | -17 | -19 |
| Outlet | -6 | -12 | -15 | -17 | |
| SQT200-ACL | Inlet | -7 | -11 | -15 | -18 |
| Outlet | -8 | -12 | -15 | -18 | |
| SQT250-ACL | Inlet | -7 | -12 | -14 | -17 |
| Outlet | -8 | -11 | -14 | -16 | |
| SQT315-ACL | Inlet | -4 | -6 | -8 | -10 |
| Outlet | -5 | -7 | -9 | -11 | |
| SQT400-ACL | Inlet | -4 | -6 | -8 | -11 |
| Outlet | -4 | -6 | -8 | -10 | |
SINGLE Phase - 220V-240V / 50Hz
AC Motors
| Product Code | dBA Attenuation | ||
|---|---|---|---|
| 1DENP | 2DENP | ||
| SQT500-ACL | Inlet | -6 | -10 |
| Outlet | -7 | -11 | |
Wiring Data
SINGLE Phase - 20V-200V / 50Hz / 60Hz
EC Motors
| Product Code | Wiring Diagram No. |
|---|---|
| SQT100-1ECL | 152-000236 |
| SQT125-1ECL | 152-000236 |
| SQT150-1ECL | 152-000236 |
| SQT200-1ECL | 152-000236 |
| SQT250-1ECL | 152-000236 |
| SQT315-1ECL | 152-000244 |
| SQT400-1ECL | 152-000244 |
| SQT500-1ECL | 152-000244 |
SINGLE Phase - 220V-240V / 50Hz
AC Motors
| Product Code | Wiring Diagram No. |
|---|---|
| SQT100-1ACL | 152-2177 |
| SQT125-1ACL | 152-2177 |
| SQT200-1ACL | 152-2177 |
| SQT250-1ACL | 152-2177 |
| SQT315-1ACL | 152-2177 |
| SQT400-1ACL | 152-2177 |
| SQT500-1ACL | 152-2177 |
THREE Phase - 380V-480V / 50Hz / 60Hz
EC Motors
| Product Code | Wiring Diagram No. |
|---|---|
| SQT500-3ECL | 152-2MOEA03K3* |
* Please contact Elta Fans for more information.
Accessories
Fast Clamps (018)
For quick connection of spigotted fans to circular duct or accessories
Read more
Silencers (068-JF)
Pre-galvanised sheet steel with perforated steel lining
Read more
Silencers (068-D**P)
Pre-galvanised sheet steel with perforated steel lining
Read more
Av Mounts (Rubber)
Spring AV mounts - zinc plated steel, rubber insert and foot pad
Read more
Flexible Connectors (018)
Read more
Panel Filters (018)
Filter access with removable panel
Read more
Electric Heater Batteries
Safe and clean heating
Read more-
Auto Changeover Panels
Auto Changeover Panels
Read more