Heat Recovery Units
Return to Heat recovery
Return to Products Heat Recovery Units
Recu & Rego
- 10 Standard sizes.
- Alternative sizes available on request.
- Air volume flow rates of up to 1.94m3/s.
- Horizontal and Vertical units available.
- Integrated control system.
>Compare
The Komfovent heat recovery units are designed to create healthy indoor air quality and comfort in hotels, schools, nurseries, offices, conference halls and other premises. They are very efficient, easy to mount and maintain.
FEATURES & BENEFITSLearn more about individual features and benefits of our products. |
SPECIFICATIONThe Heat Recovery range of hru fans as manufactured by Elta Fans Ltd. |
TECHNICAL INFORMATIONThe technical information available to you from ELTA Fans is exhaustive - Choose from either sound, performance and electrical or dimensional data for each and every product |
ACCESSORIESElta supply a full range of accessories for each of their products. |
COMPAREChoose up to three products to compare their features side-by-side. |
DOWNLOADSGet the full brochure, wiring diagrams and operation and maintenance instructions. |
Features & Benefits
Low profile
Casings are of compact design which allows ease of fitting.
Material strength
A robust unit with a double skin galvanised sheet steel casing in powder coat finish with fire resistant mineral wool infill for excellent sound characteristics.
Warranty
Komfovent Heat Recovery Unit has a 12 month warranty.
Performance
High efficiency pressed aluminium impellers are directly driven by an AC external rotor motor, designed to provide high performance characteristics.
Filtration
Units are equipped with compact, high quality air filters and filter monitoring providing customer notification of service period of filters.
Electrical
All units are suitable for 220-240V 1 phase operation or 380-440V 3 Phase dependant on model. All the AC motor specified units operate only on 50Hz whilst all EC motor specified units can operate on 50Hz or 60Hz
Quality assurance
All units are designed and manufactured with procedures as defined in BS EN ISO 9001: 2008.

Specification
Heat Recovery Units as manufactured by Elta Fans Ltd. 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US, UK. Tel: +44 (0) 1384 275800 - If you need more information - Contact us.
Casing
Panels are double skinned comprising two galvanized steel sheets, infilled with fire resistant thermal and sound attenuating insulation – mineral wool (l = 0,036W/mK). Units with 45 mm thick insulation may operate in unheated premises. Doors are manufactured with 45 mm insulation and equipped with locks. External casing surfaces are powder painted: RAL 7035 as standard preventing the unit from corrosion
Motors
Heat Recovery
SREGO units incorporate a rotary heat exchanger which recovers heat up to 90%, rotary heat exchangers work on the principle of heat recovery: a rotating aluminium rotor absorbs heat of the exhaust air and warms up the air supplied to the ventilated premises. SRECU units incorporate a plate heat exchanger which recovers heat up to 65%, the heat of the exhaust air is transferred to supply air through aluminium plates of the heat exchanger. Air flows through the heat exchanger crosswise. Unit design prevents penetration of the exhaust air to the fresh air flow
Quality Management

Technical Information
Dimensional Data
Electrical Data
SRECU-250PE-B-AC-C4
| Supply voltage | 230V/1Ph/50Hz | |
|---|---|---|
| FLC Amperes | 5.10 | |
| Control system | C4 / C4 PLUS | |
| Nominal air flow | m³/hr | 250 |
| Unit weight | kg | 40 |
| Rotary heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 80 | |
| Energy recovery | kW | 2.3 | |
| Air temperature in/out | &176;C | -23 / +13.8 | +20 / -16.8 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 58 x 2 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 1 | |
SRECU-400PE-B-AC-C4
| Supply voltage | 230V/1Ph/50Hz | |
|---|---|---|
| FLC Amperes | 5.90 | |
| Control system | C4 / C4 PLUS | |
| Nominal air flow | m³/hr | 400 |
| Unit weight | kg | 57 |
| Rotary heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 83 | |
| Energy recovery | kW | 4.6 | |
| Air temperature in/out | °C | -23 / +13.8 | +20 / -16.8 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 135 x 2 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 1 | |
SRECU400HE-R-EC-C3
| Supply voltage | 230V/1Ph/50Hz | |
|---|---|---|
| FLC Amperes | 10.7 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 400 |
| Unit weight | kg | 55 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 58.8 / 52.9 | |
| Energy recovery | kW | 2.4 | |
| Air temperature in/out | °C | -10 / +7.6 | 20 / 4.5 |
| Relative humidity in/out | °C | 82 / 20.3 | 45 / 97 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 105 x 2 |
| Speed | r/min | 3570 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 2 | |
| Air temperature in/out | kW | 7.6 / 22 | |
SRECU400HE-R-AC-C3
| Supply voltage | 230V/1Ph/50Hz | |
|---|---|---|
| FLC Amperes | 10.1 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 400 |
| Unit weight | kg | 55 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 58.8 / 52.9 | |
| Energy recovery | kW | 2.4 | |
| Air temperature in/out | °C | -10 / +7.6 | 20 / 4.5 |
| Relative humidity in/out | °C | 82 / 20.3 | 45 / 97 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 135 x 2 |
| Speed | r/min | 2650 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 2 | |
| Air temperature in/out | kW | 7.6 / 22 | |
SRECU400HE-R-AC-C3
| Supply voltage | 230V/1Ph/50Hz | |
|---|---|---|
| FLC Amperes | 10.1 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 400 |
| Unit weight | kg | 55 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 58.8 / 52.9 | |
| Energy recovery | kW | 2.4 | |
| Air temperature in/out | °C | -10 / +7.6 | 20 / 4.5 |
| Relative humidity in/out | °C | 82 / 20.3 | 45 / 97 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 135 x 2 |
| Speed | r/min | 2650 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 2 | |
| Air temperature in/out | kW | 7.6 / 22 | |
SRECU700HE-R-EC-C3
| Supply voltage | 230V/1Ph/50Hz | |
|---|---|---|
| FLC Amperes | 13.7 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 700 |
| Unit weight | kg | 75 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 57.6 / 51.9 | |
| Energy recovery | kW | 4 | |
| Air temperature in/out | °C | -10 / +7.3 | 20 / 4.7 |
| Relative humidity in/out | °C | 82 / 20.8 | 45 / 96 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 164 x 2 |
| Speed | r/min | 2570 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 2.5 | |
| Air temperature in/out | kW | 7.3 / 18 | |
SRECU700HE-R-AC-C3
| Supply voltage | 230V/1Ph/50Hz | |
|---|---|---|
| FLC Amperes | 12.9 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 700 |
| Unit weight | kg | 75 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 57.6 / 51.9 | |
| Energy recovery | kW | 4 | |
| Air temperature in/out | °C | -10 / +7.3 | 20 / 4.7 |
| Relative humidity in/out | °C | 82 / 20.8 | 45 / 96 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 240 x 2 |
| Speed | r/min | 2800 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 2.5 | |
| Air temperature in/out | kW | 7.3 / 18 | |
SRECU900HE-R-AC-C3
| Supply voltage | 400V/3Ph/50Hz | |
|---|---|---|
| FLC Amperes | 10.3 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 900 |
| Unit weight | kg | 78 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 56.5 / 50.9 | |
| Energy recovery | kW | 5.1 | |
| Air temperature in/out | °C | -10 / +7 | 20 / 4.7 |
| Relative humidity in/out | °C | 82 / 21.3 | 45 / 96 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 235 x 2 |
| Speed | r/min | 2780 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 4.5 | |
| Air temperature in/out | kW | 7 / 22 | |
SRECU1200HE-R-AC-C3
| Supply voltage | 400V/3Ph/50Hz | |
|---|---|---|
| FLC Amperes | 13.9 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 1200 |
| Unit weight | kg | 195 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 52 | |
| Energy recovery | kW | 6.3 | |
| Air temperature in/out | °C | -10 / +5.7 | 20 / 6.1 |
| Relative humidity in/out | °C | 82 / 26 | 45 / 100 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 490 x 2 |
| Speed | r/min | 1480 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 6 | |
| Air temperature in/out | kW | 5.9 / 20.9 | |
SRECU1600HE-R-AC-C3
| Supply voltage | 400V/3Ph/50Hz | |
|---|---|---|
| FLC Amperes | 26.6 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 1600 |
| Unit weight | kg | 320 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 60.3 | |
| Energy recovery | kW | 9.7 | |
| Air temperature in/out | °C | -10 / +8.1 | 20 / 5.2 |
| Relative humidity in/out | °C | 82 / 20 | 45 / 95 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 650 x 2 |
| Speed | r/min | 1480 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 12 | |
| Air temperature in/out | kW | -2.8 / +20 | |
SRECU2000HE-R-AC-C3
| Supply voltage | 400V/3Ph/50Hz | |
|---|---|---|
| FLC Amperes | 38.8 | |
| Control system | C3 | |
| Nominal air flow | m³/hr | 2000 |
| Unit weight | kg | 325 |
| Plate heat exchanger | Supply | Exhaust | |
|---|---|---|---|
| Thermal efficiency | % | 51.9 | |
| Energy recovery | kW | 10.4 | |
| Air temperature in/out | °C | -10 / +5.6 | 20 / 6.9 |
| Relative humidity in/out | °C | 82 / 23 | 45 / 90 |
| Fan Motors | ||
|---|---|---|
| Input power | Watts | 830 x 2 |
| Speed | r/min | 1480 |
| Electric Air Heater | Supply | Exhaust | |
|---|---|---|---|
| Rating | kW | 12 | |
| Air temperature in/out | kW | -2.8 / +20 | |
Sound Data
| Product Code | Sound Power Level dBW @ Octave Band Hz | dB(A) @ 3m | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 63 Hz | 125 Hz | 250 Hz | 500 Hz | 1k Hz | 2k Hz | 4k Hz | 8k Hz | ||||
| SREGO-250PE-B-AC-C4 | Supply | Inlet | 55 | 49 | 47 | 48 | 50 | 47 | 46 | 40 | 34 |
| Outlet | 59 | 59 | 58 | 57 | 57 | 55 | 53 | 51 | 42 | ||
| Extract | Inlet | 55 | 49 | 58 | 57 | 57 | 55 | 53 | 51 | 41 | |
| Outlet | 59 | 51 | 47 | 48 | 50 | 49 | 47 | 45 | 35 | ||
| Break Out | 37 | 37 | 36 | 36 | 36 | 34 | 34 | 33 | 21 | ||
| SREGO-400PE-B-AC-C4 | Supply | Inlet | 58 | 60 | 60 | 61 | 56 | 50 | 44 | 38 | 41 |
| Outlet | 62 | 69 | 71 | 71 | 66 | 58 | 53 | 48 | 51 | ||
| Extract | Inlet | 58 | 60 | 60 | 61 | 56 | 50 | 44 | 38 | 41 | |
| Outlet | 62 | 69 | 71 | 71 | 66 | 58 | 53 | 48 | 51 | ||
| Break Out | 49 | 53 | 52 | 43 | 38 | 30 | 22 | 17 | 26 | ||
| SRECU400HE-R-EC-C3 | Supply | Inlet | 52 | 54 | 55 | 55 | 51 | 46 | 42 | 38 | 35 |
| Outlet | 54 | 59 | 60 | 60 | 56 | 50 | 47 | 43 | 40 | ||
| Extract | Inlet | 52 | 54 | 55 | 55 | 51 | 46 | 42 | 38 | 35 | |
| Outlet | 54 | 59 | 60 | 60 | 56 | 51 | 47 | 44 | 40 | ||
| Break Out | 37 | 40 | 40 | 33 | 30 | 25 | 20 | 16 | 15 | ||
| SRECU400HE-R-AC-C3 | Supply | Inlet | 50 | 53 | 55 | 55 | 49 | 43 | 37 | 32 | 34 |
| Outlet | 53 | 59 | 61 | 61 | 56 | 48 | 44 | 39 | 41 | ||
| Extract | Inlet | 50 | 53 | 55 | 55 | 49 | 43 | 37 | 32 | 34 | |
| Outlet | 53 | 59 | 61 | 61 | 56 | 49 | 44 | 40 | 41 | ||
| Break Out | 35 | 39 | 37 | 29 | 25 | 18 | 11 | 6 | 12 | ||
| SRECU700HE-R-EC-C3 | Supply | Inlet | 54 | 56 | 57 | 57 | 53 | 48 | 44 | 40 | 38 |
| Outlet | 56 | 61 | 62 | 62 | 58 | 52 | 49 | 45 | 42 | ||
| Extract | Inlet | 54 | 56 | 57 | 57 | 53 | 48 | 44 | 40 | 38 | |
| Outlet | 56 | 61 | 62 | 62 | 58 | 53 | 49 | 46 | 43 | ||
| Break Out | 39 | 42 | 42 | 35 | 32 | 27 | 22 | 18 | 18 | ||
| SRECU700HE-R-AC-C3 | Supply | Inlet | 60 | 63 | 65 | 65 | 59 | 53 | 47 | 42 | 44 |
| Outlet | 63 | 69 | 71 | 71 | 66 | 58 | 54 | 49 | 51 | ||
| Extract | Inlet | 60 | 63 | 65 | 65 | 59 | 53 | 47 | 42 | 44 | |
| Outlet | 63 | 69 | 71 | 71 | 66 | 59 | 54 | 50 | 51 | ||
| Break Out | 45 | 49 | 47 | 39 | 35 | 28 | 21 | 16 | 22 | ||
| SRECU900HE-R-AC-C3 | Supply | Inlet | 58 | 61 | 63 | 63 | 57 | 51 | 45 | 40 | 42 |
| Outlet | 61 | 67 | 69 | 69 | 64 | 56 | 52 | 47 | 49 | ||
| Extract | Inlet | 58 | 61 | 63 | 63 | 57 | 51 | 45 | 40 | 42 | |
| Outlet | 61 | 67 | 69 | 69 | 64 | 57 | 52 | 48 | 49 | ||
| Break Out | 43 | 47 | 45 | 37 | 33 | 26 | 19 | 14 | 20 | ||
| SRECU1200HE-R-AC-C3 | Supply | Inlet | 46 | 49 | 51 | 51 | 45 | 39 | 33 | 28 | 30 |
| Outlet | 49 | 55 | 57 | 57 | 52 | 44 | 40 | 35 | 36 | ||
| Extract | Inlet | 46 | 49 | 51 | 51 | 45 | 39 | 33 | 28 | 30 | |
| Outlet | 49 | 55 | 57 | 57 | 52 | 45 | 40 | 36 | 36 | ||
| Break Out | 31 | 35 | 33 | 25 | 21 | 14 | 7 | 2 | 7 | ||
| SRECU1600HE-R-AC-C3 | Supply | Inlet | 49 | 52 | 54 | 54 | 48 | 42 | 36 | 31 | 33 |
| Outlet | 52 | 58 | 60 | 60 | 55 | 47 | 43 | 38 | 40 | ||
| Extract | Inlet | 49 | 52 | 54 | 54 | 48 | 42 | 36 | 31 | 33 | |
| Outlet | 52 | 58 | 60 | 60 | 55 | 48 | 43 | 39 | 40 | ||
| Break Out | 34 | 38 | 36 | 28 | 24 | 17 | 10 | 5 | 11 | ||
| SRECU2000HE-R-AC-C3 | Supply | Inlet | 48 | 50 | 50 | 50 | 46 | 40 | 35 | 29 | 30 |
| Outlet | 50 | 55 | 55 | 56 | 53 | 45 | 41 | 36 | 36 | ||
| Extract | Inlet | 48 | 50 | 50 | 50 | 46 | 40 | 35 | 29 | 30 | |
| Outlet | 50 | 55 | 55 | 56 | 53 | 46 | 42 | 37 | 37 | ||
| Break Out | 34 | 38 | 36 | 28 | 24 | 17 | 10 | 5 | 11 | ||
Tests and preparation of the sound data have been carried out in accordance with BS 848 Part 2:1985 at 50% peak pressure.
The In-duct Sound Power Level Spectra are in dB re-1pW.
The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in dB re-20µPa and is presented for comparative purposes only.
Accessories
Non-Return Dampers (018)
Prevents reverse flow of air when fan not operating
Read more
Fast Clamps (018)
For quick connection of spigotted fans to circular duct or accessories
Read more
Silencers (068-JF)
Pre-galvanised sheet steel with perforated steel lining
Read more